1.6 CONNECTING TO WATER SUPPLY LINES
A. Use a filter in the water line to avoid equipment damage and beverage off-taste. Check the
water filter periodically, as required by local conditions.
B. Protect the water supply by means of an air gap, a backflow prevention device, or another
approved method that complies with NSF standards. A leaking inlet water check valve will allow
carbonated water to flow back through the pump when it is shut off and contaminate the water
supply. Ensure the backflow prevention device complies with ASSE and local standards.
It is
the responsibility of the installer to ensure compliance.
C. Provide an adequate potable water supply. Water pipe connections and fixtures directly
connected to a potable water supply must be sized, installed, and maintained according to
federal, state, and local laws.
D. For the plain water supply line, the inlet water flowing pressure should be at least 75 PSI. If the
water pressure is lower than 75 PSI flowing, use a water booster system.
If the water flowing pressure is lower than 75 PSI at the plain water inlet and a water booster is
NOT installed, water products will not hold a proper flow rate or water/syrup ratio. Flow
conditions at the nozzle can also be affected, causing poor nozzle coning and mixing.
NOTE:
The Lancer Water Booster/Tank (PN
is offered as a kit. The water booster
must be installed as close as possible to the plain water circuit inlet.
E. For the soda water supply line, do not exceed 50 PSI for the inlet water static pressure going
into the carbonator pump. If the static water pressure exceeds 50 PSI, install a water regulator
before the carbonator water inlet.
NOTE:
Install the water regulator (Lancer PN
included with unit as close as possible
to the water carbonator pump inlet. The recommended water pressure value feeding the
carbonator is a minimum of 25 PSI. If the normal water pressure does not exceed 50 PSI, but
fluctuates over this value (for example, when water usage on other equipment connected to the
same water supply causes pressure spikes), use a water regulator.
WARNING!
Do not connect to a hot water or soft water source. This causes excessive
foaming.
WARNING!
Do not operate the carbonator pump with the water supply off. Doing so can
damage components and void the warranty.