TROUBLE
CAUSE
REMEDY
CONTINUED ON NEXT PAGE
4.19
Water continually leaking at
connections.
A. Loose water connections.
B. Flare seal washer leaks.
A. Tighten water connections.
B. Replace flare seal washer.
4.20
Circuit breaker tripping.
A. Valve wire harness shorted to
itself or faucet plate.
B. Controller PCB is bad.
C. Secondary wire harness is
shorted.
D. power supply is bad.
A. Detect short by disconnecting
valve harnesses from switch
panel (4 25-pin harnesses and 4
9-pin harnesses). Restore power.
If breaker does not trip, find and
replace shorted harness. If
breaker trips, re-install the 8
harnesses, and proceed to step
B.
B. Detect by disconnecting the
white 5-pin harness from the
controller PCB. Restore power. If
breaker does not trip, replace
controller PCB. If breaker trips,
re-install the white 5-in harness
and proceed to step C.
C. Locate short from a motor or
solenoid harness and replace.
D. Detect short by disconnecting
all harnesses connected to power
supply. Restore power. If breaker
still trips, replace power supply.
4.21
BIB pump does not operate
when dispensing valve is opened.
A. Out of CO
2
, CO
2
not turned
on, or low CO
2
pressure.
B. Out of syrup.
C. BIB connector not tight.
D. Kinks in syrup or gas lines.
A. Replace CO
2
supply, turn on
CO
2
supply, or adjust CO
2
pressure to 70-80 PSI.
B. Replace syrup supply.
C. Fasten connector tightly.
D. Straighten or replace lines.
4.22
BIB pump operating, but no
flow.
A. Leak in syrup inlet or outlet
line.
B. Defective BIB pump.
A. Replace line.
B. Replace BIB pump.