7. Commissioning
1.
Purge all dispensing lines of air by cycling through the flavours on each bar gun and check for leaks.
Repair as required before proceeding.
2.
Dispense soda from a valve or Bargun until the pump starts on the FlexiCarb. Close the valve and
allow the FlexiCarb to cycle off to check if the FlexiCarb is operating properly.
3.
Fill ice well at least 2/3 full and allow to set 10-15 minutes prior to setting the dispenser flow rates and
brix ratios.
Caution
Do not use sub-cooled ice
8. Scheduled
Maintenance
Warning
The Drop In exterior must not be cleaned by a water jet.
8.1. Daily
Cleaning/Sanitising
To ensure optimum drink quality and system performance at all times please follow cleaning and
sanitising procedures for the dispensing valves/barguns recommended by the valve/bargun
manufacturer.
Checking CO
2
Supply
Ensure that the contents gauge on the CO
2
Regulator reads higher than 1400kpa on the dial. If it
does not, then the CO
2
cylinder is empty and must be changed using safe working practices.
Warning
To avoid personal injury and/or property damage, always
secure the CO
2
cylinder with a safety chain to prevent it from
falling over; and use appropriate protective equipment (as
defined in Clause 3.3.2 of AS 5034) to handle cylinders.
Should the valve become accidentally damaged or broken
off, a CO
2
cylinder can cause serious personnel injury.
8.2. Quarterly
The Drop In should be connected to a filtered water supply. To ensure optimum drink quality and
system performance, water filters should be replaced every 3 months.