6.7 Connecting to CO2 supply
Warning
As carbon dioxide (CO2) displaces oxygen; prevention of CO2
leaks is paramount. If a leak is suspected, immediately ventilate
the contaminated area, before attempting repairs.
1. Connect
CO
2
supply line from regulator to the 6mm gas inlet on carbonator.
2.
Turn on CO2 Supply
3. Adjust
CO
2
Regulator supplying Carbonator to 520 kPa for chilled inlet water.
4.
Check for leaks with a mild soap solution and repair as required before continuing.
6.8 Plumbing the CO2 exhaust vent
A 6mm plastc barb is provided to vent any escaped CO2 to a naturally ventilated area in accordance
with AS 5034 gas standards.
6.9 Electrical
Connection
1.
This unit is connected to the supply via a 10 amp flexible cord fitted with a 3 pin plug.
2.
Check the name plate on the machine for electrical supply requirements. Use only the power
supply specified on the name plate.
Warning
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
Warning
To avoid possible fatal electric shock or serious injury the FlexiCarb
must be electrically grounded.
Electrical Connection Must Be Made In Accordance With The
Appropriate Local Codes And Regulations.
Use of an RCD is recommended.
Vent barb