Dropin 1522 Bargun
www.lancerbeverage.com
Page 12 of 25
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No 68000014
Images are for illustration purposes only as product may vary.
No 030b-12 August 2013
Recommended Jumper Lengths
PART NUMBER
DESCRIPTION
79221203 CLAMP
STEPLESS S/S 118
JUMPER 2
TUBE LDP 6MM U/V BLACK X 320MM
JUMPER 3
TUBE LDP 6MM U/V BLACK X 320MM
JUMPER 4
TUBE LDP 6MM U/V BLACK X 320MM
JUMPER 5
TUBE LDP 6MM U/V BLACK X 270MM
JUMPER 6
TUBE LDP 6MM U/V BLACK X 270MM
JUMPER 7
TUBE LDP 6MM U/V BLACK X 380MM
JUMPER 8
TUBE LDP 6MM U/V BLACK X 270MM
JUMPER 9
TUBE LDP 6MM U/V BLACK X 400MM
INSOLEX J2
INSOLEX 10MM ID X 9MM W X 370MM
INSOLEX J3
INSOLEX 10MM ID X 9MM W X 370MM
INSOLEX J4
INSOLEX 10MM ID X 9MM W X 370MM
INSOLEX J5
INSOLEX 10MM ID X 9MM W X 320MM
INSOLEX J6
INSOLEX 10MM ID X 9MM W X 320MM
INSOLEX J7
INSOLEX 10MM ID X 9MM W X 420MM
INSOLEX J8
INSOLEX 10MM ID X 9MM W X 320MM
INSOLEX J9
INSOLEX 10MM ID X 9MM W X 450MM
6.6 Connecting Water and Syrups
1.
Using appropriate tubing and fittings connect a 10mm water supply line from the Drop In
WATER IN to a filtered, regulated water supply. Installation in accordance with AS/NZS 3500.1
and AS/NZS 3500.2.
2.
Turn on water supply, check for leaks and adjust water regulator to 380 kPa.
3.
Open the carbonator relief valve until water flows from CO2 exhaust tube; then close the relief
valve.
4.
Connect the syrups to the Drop In according to the connection diagram on the front of the Drop
In.
Warning
The water inlet has to be supplied through a water tap that is
installed in accordance with plumbing rules and regulations.
Caution