Recommended  Jumper Lengths 

 

PART NUMBER 

DESCRIPTION 

79221203 CLAMP 

STEPLESS S/S 118 

JUMPER 2 

TUBE LDP 6MM U/V BLACK X 320MM 

JUMPER 3 

TUBE LDP 6MM U/V BLACK X 320MM 

JUMPER 4 

TUBE LDP 6MM U/V BLACK X 320MM 

JUMPER 5 

TUBE LDP 6MM U/V BLACK X 270MM 

JUMPER 6 

TUBE LDP 6MM U/V BLACK X 270MM 

JUMPER 7 

TUBE LDP 6MM U/V BLACK X 380MM 

JUMPER 8 

TUBE LDP 6MM U/V BLACK X 270MM 

JUMPER 9 

TUBE LDP 6MM U/V BLACK X 400MM 

INSOLEX J2 

INSOLEX 10MM ID X 9MM W X 370MM 

INSOLEX J3 

INSOLEX 10MM ID X 9MM W X 370MM 

INSOLEX J4 

INSOLEX 10MM ID X 9MM W X 370MM 

INSOLEX J5 

INSOLEX 10MM ID X 9MM W X 320MM 

INSOLEX J6 

INSOLEX 10MM ID X 9MM W X 320MM 

INSOLEX J7 

INSOLEX 10MM ID X 9MM W X 420MM 

INSOLEX J8 

INSOLEX 10MM ID X 9MM W X 320MM 

INSOLEX J9 

INSOLEX 10MM ID X 9MM W X 450MM 

 

 

6.6  Connecting Water and Syrups 

1. 

Using appropriate tubing and fittings connect a 10mm water supply line from the Drop In 

WATER IN to a filtered, regulated water supply.  Installation in accordance with AS/NZS 3500.1 

and AS/NZS 3500.2. 

2. 

Turn on water supply, check for leaks and adjust water regulator to 380 kPa.

 

3. 

Open the carbonator relief valve until water flows from CO2 exhaust tube; then close the relief 

valve. 

4. 

Connect the syrups to the Drop In according to the connection diagram on the front of the Drop 

In. 

 

Warning 

The water inlet has to be supplied through a water tap that is 
installed in accordance with plumbing rules and regulations. 

 

 

Caution 

Maximum water supply pressure to be 380 kpa. 

Содержание DROPIN 1522 Bargun

Страница 1: ...www lancerbeverage com Installation Operation Service Manual Dropin 1522 Bargun With Flexicarb 230V 50Hz...

Страница 2: ...ge com Page 2 of 25 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000014 Images are for illustration purposes only as product may vary No 030b 12 August 2013 Thi...

Страница 3: ...ating 7 5 4 Service Maintenance 7 5 5 Carbon Dioxide CO2 8 6 Installation 8 6 1 Receiving 8 6 2 Unpacking 8 6 3 Selecting a Location 8 6 4 Assembling the FlexiCarb 9 6 5 Installation 10 6 6 Connecting...

Страница 4: ...turn ultimately owned by Hoshizaki Electric Co Ltd of Nagoya Japan Hoshizaki is a global leader in food service equipment Hoshizaki Lancer s Australian head office and manufacturing base is located in...

Страница 5: ...actured ice cooled post mix dispensing system with integrated mounts for up to 2 bar guns plus a single carbonator designed for smaller installations and limited access areas It is specifically design...

Страница 6: ...requency 50 Hz Max Current Draw 0 5 Amps Ambient Temperature 2 40 C Max Water Inlet Pressure 380 kPa CO2 Gas Pressure 520 kPa with chilled water inlet recommended Carbonator Capacity 1 litre nominal C...

Страница 7: ...es throughout this manual To prevent personal injury or damage to the machine these alerts must be strictly adhered too Warning Alerts to a potentially hazardous situation that if not avoided CAN resu...

Страница 8: ...of consciousness and suffocation If a CO2 gas leak is suspected immediately ventilate the contaminated area before attempting to repair the leak 6 Installation 6 1 Receiving Each unit is completely t...

Страница 9: ...geration dish washers etc 6 4 Assembling the FlexiCarb The preferred method of mounting the FlexiCarb to the Drop In is provided as an integral solution Mounting holes and hardware are provided on the...

Страница 10: ...device to work properly 4 Use any of the mounting holes provided to secure the carbonator in place We suggest using 6mm diameter or larger screws 5 Insulate all lines to and from the Drop In 6 5 Insta...

Страница 11: ...and attach the gun to the plate with the wing nuts and thumbscrews provided 8 Connect the dropin to the bargun with insulated tubing jumpers with clamps as shown below Follow the connection label on...

Страница 12: ...LEX 10MM ID X 9MM W X 370MM INSOLEX J5 INSOLEX 10MM ID X 9MM W X 320MM INSOLEX J6 INSOLEX 10MM ID X 9MM W X 320MM INSOLEX J7 INSOLEX 10MM ID X 9MM W X 420MM INSOLEX J8 INSOLEX 10MM ID X 9MM W X 320MM...

Страница 13: ...lution and repair as required before continuing 6 8 Plumbing the CO2 exhaust vent A 6mm plastc barb is provided to vent any escaped CO2 to a naturally ventilated area in accordance with AS 5034 gas st...

Страница 14: ...not be cleaned by a water jet 8 1 Daily Cleaning Sanitising To ensure optimum drink quality and system performance at all times please follow cleaning and sanitising procedures for the dispensing valv...

Страница 15: ...e com Page 15 of 25 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000014 Images are for illustration purposes only as product may vary No 030b 12 August 2013 9 E...

Страница 16: ...B 1L 3 15000121 KWICK MOUNT KIT FLOW REG WBAR 4 79000402 SCREW 3 16 BSW X PH PHP S S 5 79000440 WASHER FLAT 10D X 5 16 ID S S 6 79000422 SCREW S S 1 4BSW X 1 2 PAN PHILLIPS HEAD 7 81000072 TUBE LDP 10...

Страница 17: ...un www lancerbeverage com Page 17 of 25 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000014 Images are for illustration purposes only as product may vary No 030...

Страница 18: ...nge specifications without notice Part No 68000014 Images are for illustration purposes only as product may vary No 030b 12 August 2013 10 2 Parts list Ref Description 1 PANEL MOUNTING FLEXICARB 1L 2...

Страница 19: ...Description 1 79000683 BFV WATTS 9DB AUS COMPLIANT 2 79117818 TAIL S S 10MM BARB 3 8 NUT 3 79158134 SEAL NYLON 3 8 FLARE 4 79000206 NUT SWIVEL 3 8 FL CHROME 5 66000031 DIRECTOR BR 1 8NPT X 6MM BARB 6...

Страница 20: ...Flexicarb Pump Assy Ref HL Part No Description 1 24000039 PUMP TRIPLEX MODEL R3811503B 23000100 PUMP KIT FLEXICARB 2 79000338 FITTING S S 3 8 FLARE X 3 8 NPT 3 81000502 1 INSULATION KIT FLEXICARB PUMP...

Страница 21: ...79000334 ELBOW SWIVEL 10MM X 3 8 FL FEM 7 79000335 ELBOW SWIVEL 6MM X FLARE FEMAL 8 79158146 SEAL NYLON 1 4 FLARE 9 08000001 CARB RELIEF ASS CHUDNOW AS5034 10 23000005 CARBONATOR 1L FLEXICARB W SWITCH...

Страница 22: ...un www lancerbeverage com Page 22 of 25 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000014 Images are for illustration purposes only as product may vary No 030...

Страница 23: ...out notice Part No 68000014 Images are for illustration purposes only as product may vary No 030b 12 August 2013 10 6 Flexicarb Junction Box Ref HL Part No Description 1 83000309 FLEXICARB JUNCTION BO...

Страница 24: ...Lancer will not normally cover any labour costs associated with a warranty claim Subject to the approval of the Divisional Sales Manager Lancer may choose to reimburse the customer for some or all la...

Страница 25: ...ed by Date TAG No P MIX REF All motors and pumps secured and mounted correctly All pumps run quietly and carbonator pump switched O K Carbonator and plumbing pressure tested Check for leaks on pumps c...

Отзывы: