![lancer DROPIN 1522 Bargun Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/lancer/dropin-1522-bargun/dropin-1522-bargun_installation-operation-and-service-manual_3520785008.webp)
Dropin 1522 Bargun
www.lancerbeverage.com
Page 8 of 25
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No 68000014
Images are for illustration purposes only as product may vary.
No 030b-12 August 2013
Warning
Carbonator contains CO2 gas and water under pressure. De-
pressurise before performing any work on the system.
Warning
ALL WIRING AND PLUMBING MUST CONFORM TO LOCAL
AND NATIONAL CODES.
Warning
THE DROP IN MUST BE ISOLATED FROM ELECTRICAL
SUPPLY BEFORE COMMENCING ANY SERVICE OR
MAINTENANCE WORK.
5.5
Carbon Dioxide (CO2)
Warning
The Drop In uses a CO2 (Carbon Dioxide) supply. CO2 is a
heavier than air, colourless, non-combustible gas with a faintly
pungent odour.
Personnel exposed to high concentrations of CO2 gas will
experience tremors, which are followed rapidly by loss of
consciousness and suffocation.
If a CO2 gas leak is suspected, immediately ventilate the
contaminated area before attempting to repair the leak.
6. Installation
6.1 Receiving
Each unit is completely tested under operating conditions and thoroughly inspected before shipment.
At time of shipment, the carrier accepts the unit and any claim for damage(s) must be made with the
carrier. Upon receiving units from the delivering carrier, carefully inspect shipping crate for visible
indication(s) of damage. If damage exists, have carrier note damage on bill of landing and file a claim
with the carrier.
6.2
Unpacking
Carefully unpack the Drop In and remove the Flexicarb, drain hose assembly and other contents
from the ice well. Inspect unit for concealed damage and if evident, notify delivering carrier and file a
claim against the carrier.
6.3
Selecting a Location
Warning
Drop Ins with FlexiCarbs are intended for indoor operation only;
do not operate outside unless suitably protected by a
weatherproof enclosure.