background image

3

IMPORTANT SAFETY INSTRUCTIONS

• 

The dispenser is for indoor use only

• 

This appliance is intended to be used in commercial 

applications such as restaurants or similar.

• 

This appliance should not be used by children or 

infirm persons without supervision. 

• 

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and       

knowledge, unless they have been given supervision 

or instruction concerning use of the appliance by a 

person responsible for their safety. 

• 

This appliance can be used by children aged from 8 

years and above and persons with reduced physical, 

sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or 

instruction concerning use of the appliance in a safe 

way and understand the hazards involved.

• 

Cleaning and user maintenance shall not be          

performed by children without supervision.

• 

This unit is not a toy and children should be advised 

not to play with the appliance.

• 

The min/max ambient operating temperature for the 

dispenser is 40°F to 75°F (4°C to 24°C). 

• 

Do not operate unit below minimum ambient operation 

conditions. 

• 

Should freezing occur, cease operation of the unit and 

contact authorized service technician.

• 

The maximum tilt for safe operation is 5°. 

• 

This appliance must be installed and serviced by a 

professional.

Intended Use

• 

Follow all local electrical codes when making         

connections.

• 

Check the dispenser name plate label, located behind 

the front panel, for the correct electrical requirements 

of unit. 

DO NOT

 plug into a wall electrical outlet      

unless the current shown on the serial number plate 

agrees with local current available.

• 

Each dispenser must have a dedicated electrical 

circuit. 

•  DO NOT

 use extension cords with this unit. 

DO NOT

 

‘gang’  together with other electrical devices on the 

same outlet.

•  WARNING: 

Always disconnect electrical power to the 

unit to prevent personal injury before attempting any 

internal maintenance. 

• 

The resettable breaker switch should not be used as 

a substitute for unplugging the dispenser from the 

power source to service the unit. 

• 

Only qualified personnel should service internal    

components of electrical control housing. 

•  WARNING: 

Make sure that all water lines are tight and 

units are dry before making any electrical connections 

• 

If this dispenser is installed in an area that is          

susceptible to more than 10% variation of the nominal 

line voltage, consider installing a surge protector or 

similar protection device.

Power

•  WARNING:

 Carbon Dioxide (CO

2

) is a colorless,      

noncombustible gas with a light pungent odor. High 

percentages of CO

2

 may displace oxygen in the 

blood. 

•  WARNING: 

Prolonged exposure to CO

2

  can  be  harmful.           

Personnel exposed to high concentrations of CO

2

 gas 

will experience tremors which are followed by a loss 

of consciousness and suffocation. 

•  WARNING: 

If a CO

2

 gas leak is suspected, immediately 

ventilate the contaminated area before attempting to 

repair the leak. 

•  WARNING: 

Strict attention must be observed in the 

prevention of CO

2

 gas leaks in the entire CO

2

 and soft 

drink system.

Carbon Dioxide (CO

2

)

• 

Provide an adequate, potable water supply. Water 

pipe connections and fixtures directly connected to 

a potable water supply must be sized, installed, and 

maintained according to federal, state, and local 

codes.

• 

The water supply line must be at least a 3/8 inches 

(9.525 mm) pipe with a minimum of 25 psi (0.172 

MPa) line pressure, but not exceeding a maximum 

of 65 psi (0.448 MPa).  Water pressure below 

25 psi 

(0.172 MPa) will require the use of a water booster, 

(82-3401 or MC-163172).

 Water pressure exceed-

ing 65 psi (0.448 MPa) must be reduced by way of a 

water regulator (18-0253/02).

• 

Use a filter in the water line to avoid equipment    

damage and beverage off-taste. Check the water filter 

periodically, as required by local conditions.

•  CAUTION: 

The water supply must be protected by 

means of an air gap, a backflow prevention device 

(located upstream of the CO

2

 injection system) 

or another approved method to comply with NSF           

standards. A leaking inlet water check valve will         

allow carbonated water to flow back through the pump 

when it is shut off and contaminate the water supply.

•  CAUTION: 

Ensure the backflow prevention device   

complies with ASSE and local standards. It is the 

responsibility of the installer to ensure compliance.

Water Notice

Содержание Barrilitos Beverage Tower

Страница 1: ...Lancer 2018 by Lancer all rights reserved 330 Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Tech Support Warranty 800 729 1550 email custserv lancercorp com web lancercorp...

Страница 2: ...Switch Settings 20 Plumbing Diagram 21 SAFETY NOTICES READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT This manual contains important safety information and all applicable safety precautions must...

Страница 3: ...e dispenser from the power source to service the unit Only qualified personnel should service internal components of electrical control housing WARNING Make sure that all water lines are tight and uni...

Страница 4: ...ounces per second PLAIN WATER SUPPLY Min Flowing Pressure 25 psi 0 172 MPa Max Static Pressure 65 psi 0 448 MPa CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FI...

Страница 5: ...level Can the countertop support the weight of the dispenser Include the weight of an ice machine plus weight of ice if necessary Is dispenser located away from direct sunlight or overhead lighting T...

Страница 6: ...and file a claim against the same NOTE Inspect the counter location where the unit is to be installed Verify the selected counter is strong enough to safely support the weight of the installed unit af...

Страница 7: ...ust be sealed to the counter NOTE 8 Slide drip tray into opening in tower until magnets engage and lock drip tray in place The installation and relocation if necessary must be carried out by qualified...

Страница 8: ...tray Adjust Water Flow Rate Syrup Water Ratio 1 Remove the front panel from the tower by pulling away from the unit and disengaging the magnets 2 Use the brand buttons to enter the Technician Mode see...

Страница 9: ...r after 15 seconds Deselecting a Brand 1 The selected brands LED is ON and the light ring matches the color specified by the as sociated DIP switch configuration 2 Brand button is automatically desele...

Страница 10: ...to cancel pour in progress Timed Pour of Syrup 1 The lever is in the OFF state and no brand is selected 2 Pull and release lever 5 times within a span of 5 seconds Pulls must be within 1 second of ea...

Страница 11: ...rgent e g Sodium Laureth Sulfate dish soap with clean potable water at a temperature of 90 F to 110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a minimum o...

Страница 12: ...ft cloth and cleaning solution clean the nozzle injectors See Cleaning and Sanitizing Nozzle section on page 12 for reference Remove cup rest and wash in warm soapy water Pour warm soapy water into th...

Страница 13: ...1 O ring is damaged or missing 1 Replace o ring Miscellaneous leakage 1 Gap between parts 2 Damaged or improperly installed o rings 1 Tighten appropriate retaining screws 2 Replace or adjust appropri...

Страница 14: ...f the dispenser 4 Check the CO2 pressure to the pump manifold to ensure it is between 70 and 80 psi 0 483 and 0 552 MPa 5 Check CO2 pressure and or replace pump 6 Remove kink or replace line Syrup onl...

Страница 15: ...f CO2 CO2 not turned on or low CO2 pressure 2 Out of syrup 3 BIB connector not tight 4 Kinks in syrup or gas lines 5 Bad BIB Pumps 1 Replace CO2 supply turn on CO2 supply or adjust CO2 pressure to 70...

Страница 16: ...06 01 2991 Coupling Female 07 82 5000 Drain Kit BBT 08 05 3719 01 Splash Plate BBT 09 82 5290 Faucet Housing Assy BBT 10 54 0557 Nozzle Assy BBT 11 19 0560 Valve Assy CVM Water 2 0 oz 12 19 0559 Valv...

Страница 17: ...3756 Faucet Handle BBT 02 05 3757 Faucet Cam BBT 03 10 1019 Actuator Pin 04 04 0549 Screw 6 19 x 0 625 05 05 3765 Washer 06 05 3759 Upper Faucet Housing BBT 07 03 0530 Faucet Spring 08 82 5297 Actuat...

Страница 18: ...18 Button Panel Assembly 01 x4 03 04 02 Item Part No Description 01 04 1639 01 Screw 4 20 x 0 250 02 52 3956 Buttons Harness BBT 03 05 3726 Button Panel BBT 04 82 5298 Button PCB Assembly...

Страница 19: ...19 Wiring Diagram...

Страница 20: ...ailable on the Barrilitos Tower NOTE DIP Switch Config Color Brand Name Mango Lime Switch 1 Default Position Pear Cucumber Switch 2 Default Position Pineapple Switch 3 Default Position Strawberry Hibi...

Страница 21: ...S4 Syrup Line 4 PW Plain Water Line To prevent possible harm to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was...

Страница 22: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: