138
10
Appendix
10.13 Accessories and Spare Parts
Storage of the target values and variable data
In EEPROM up to 20 points per curve with linear interpolation
Number of programmings
2 per channel (e.g. for oil/gas combined burner)
Optionally 4 and 8
Number of programmings
Unlimited (EEPROM)
Interface
2 serial interfaces on 25-pole Sub-D socket only addressable
via adapter
RS232 (standard setting 19200 baud, even parity, 8, 1) and
AMTEC SYSTEM BUS
BUS coupling
Via 25-pole Sub-D socked
Optional BUS card for the following systems:
INTERBUS-S (Phoenix)
PROFIBUS DP
Modbus
Ethernet (Modbus TCP)
Characteristics
Environmental conditions
Ambient temperature
– Operation
+0 °C ... +60 °C (32 °F ... 140 °F)
– Transport and storage
-25 °C ... +60 °C (-13 °F ... 140 °F)
Permiss. ambient humidity
Class F, DIN 40 040
Accessories for VMS
Oder no.
Novotechnik potentiometer 5 k
, für VR, VMS/FMS TÜV approved
660P7001
Contelec potentiometer 5 k
, for VR, VMS/FMS TÜV approved
660P7003
Contelec potentiometer 5 k
,for VR, VMS/FMS TÜV-approved, short axis for conversion of L & G motors
660P7002
Contelec-Potentiometer 5 k
to 90° for conversion of Autoflame motors
660P7004
Servomotor 12 Nm, running time 60 s to 90°, 2 limit switches, incl. TÜV approved potentiometer
662R2110
Servomotor19 Nm, running time 60 s to 90°, 2 limit switches, incl. TÜV-approved potentiometer
662R2111
Servomotor 30 Nm, running time 60 s to 90°, 3 limit switches, manual operation, incl. TÜV approved potenti-
ometer
662R2112
Buffer amplifier TUI 21 (0 … 20 mA/0 … 20 mA)
655R0100
Buffer amplifier TUI 21 (input and output set at factory)
655R0101
Module for signal inputs 230 V
660R0018
PC Remote Software for VMS/FMS
663R9000
PC Remote Software for VMS/FMS (end user version)
663R9001
Spare parts for VMS
Order no.
Fuses 1 A, T for VMS/FMS, 24 V supply (package of 10)
660R0110
Fuses 0,315 A, T for VMS/FMS, 230 V (package of 10)
660R0116
Fuses 3,15 A, T for relay module 660R0011/R0012/R0014/R0131 (package of 10)
660R0115
Fuses 80 mA, T for relay module 660R0013 (package of 10)
660R0113
Fuses 2 A, T for relay module 660R0016 (package of 10)
660R0114
Fuses 0,5 A, T for relay module 660R0016 (package of 10)
660R0117
Program Up-Date VMS/FMS
663R3100
Plug connector 18 pole for VMS/FMS
655P9211
Содержание VMS Series
Страница 1: ...www lamtec de Sensors and Systems for Combustion Technology Manual Fuel Air Ratio Control System VMS...
Страница 2: ......
Страница 119: ...118 10 Appendix...
Страница 121: ...120 10 Appendix 10 6 Process Sequence Charts Fig 10 3 Sequence of functions VMS digital inputs sequencer...
Страница 129: ...128 10 Appendix Fig 10 9 Ger t 4 Ger t 5 with output regulator...
Страница 141: ...140 10 Appendix 10 14 Declaration of Conformity...
Страница 142: ...141 10 Appendix...
Страница 143: ...142 10 Appendix 10 15 Protocol Example...
Страница 144: ...143 10 Appendix 10 16 O2 Setpoint Curves...
Страница 145: ...144 10 Appendix...