Configuration of the switching outputs and alarms
Ser[LOG] has two built-in potential-free bistable relays. If the supply voltage of the Ser[LOG] is
switched off, these relays remain in the last switched position. The activation of the relays takes place
via the switching output logic of the Ser[LOG]. A total of up to 10 switching channels can be configured,
of which the first two channels are permanently connected to the two relays, with channel 1 on relay
output R1 and channel 2 on relay output R2.
The other switching channels can be used for external Modbus relays, for triggering email or SMS
alarms. The assignment of the switching channels to the used Modbus relays is made via the "Actua-
tors" tab. See chapter 7.4.3 for more information.
The configuration of email alarms is described in chapter 6.1.1.3 "Transmission of measured values
via email / email alarm".
The configuration of SMS alarms is described in chapter 6.1.1.6 "Setting SMS alarm".
As soon as the Ser[LOG] is switched on, the relays are first initialized, then the Ser[LOG] switches the
relays according to the set logic.
The switching channels are configured individually for each channel. The switching channel to be
configured is selected in the "Channel" selection box. The following 4 control and monitoring functions
are available for each switching channel:
•
Process control
•
Cycle control
•
fault monitoring
•
Area monitoring
Содержание Ser[LOG]
Страница 9: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 9 of 129 21 Technical data 127 22 Disposal 129...
Страница 68: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 68 of 129 This choice leads to the following graph...
Страница 92: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 92 of 129 12 Managing the safety settings...
Страница 101: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 101 of 129...
Страница 102: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 102 of 129...
Страница 103: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 103 of 129...
Страница 104: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 104 of 129...
Страница 105: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 105 of 129...
Страница 106: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 106 of 129...
Страница 107: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 107 of 129...