LAMBRECHT meteo GmbH
Ser[LOG] Manual
Page 40 of 129
4.10
Other functions
By pressing the button
you open a menu, which can be used to access other rarely used
functions.
Read USB stick
Reads an existing configuration from the USB stick and automatically
adds it to the station database if it does not already exist. At the same
time, measured values stored on the USB stick are read out and
saved in a CSV file.
Security settings
Function for setting up and managing access protection to the
Commander and loggers.
CSV settings
Function for setting the date format, decimal points and field sepa-
rators for formatting the saved measured values.
Export station data
Export one or more station configurations.
Import station data
Import one or more station configurations.
Sensor selection
´My Sensors only`
Pre-selection of sensors to be used for logger configuration. Im-
proves the overview when configuring.
Export sensor data
Export one or more sensor configurations.
Import sensor data
Import one or more sensor configurations.
Reorganize database
Rebuilding and summarizing the data files (station, sensor, relay)
View PDF document
Simple PDF viewer for reading connection diagrams or this manual,
for example.
Display status codes
Display of the status codes that were transferred with the read-out
measured values.
Language
Change the language (currently German and English are available).
After the selection, the Ser[LOG]-Commander is closed and must
be restarted.
5
Commissioning / basic configuration
5.1
Connecting sensors
Connect the sensors to the Ser[LOG] according to chapter 2 (wiring - device connection) and accord-
ing to the used signals.
Make a note of the inputs to which the sensors have been connected. We recommend that you use
the tables in Appendix 17. The information entered in the tables will later simplify the configuration of
the Ser[LOG] with the Ser[LOG]-Commander.
5.2
Connecting to the supply voltage
After the sensors have been connected, connect them to the supply voltage.
Note:
Please note that the Ser[LOG] must be supplied with 10...30 VDC and that this supply voltage is
transmitted via the Ser[LOG]-Bus to the "SENSOR SUPPLY" terminals of the AnDiMod.
Содержание Ser[LOG]
Страница 9: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 9 of 129 21 Technical data 127 22 Disposal 129...
Страница 68: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 68 of 129 This choice leads to the following graph...
Страница 92: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 92 of 129 12 Managing the safety settings...
Страница 101: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 101 of 129...
Страница 102: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 102 of 129...
Страница 103: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 103 of 129...
Страница 104: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 104 of 129...
Страница 105: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 105 of 129...
Страница 106: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 106 of 129...
Страница 107: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 107 of 129...