29
Wear personal protective gear (such as protective footwear and protective gloves).
Do not walk or stand under a suspended load.
Use only suitable means of transport (such as an industrial or lift truck).
Use only industrial trucks with appropriate capacity for loading. Unit weight – Refer to
Secure the unit so that it cannot tip or fall.
Transportation on casters
The unit is equipped with lockable casters on the front end of the unit. The casters on the back end of
the unit are non-lockable. To transport the unit over short distances, the unit can be moved on these
casters. Extra care should be taken when transporting the unit over gaps in the floor, such as when
entering / exiting an elevator.
Damage to property due to tipping of the unit.
When rollers are blocked by obstacles, there is a risk that the unit may tip.
Move the unit slowly and carefully over flat surfaces.
Keep possible obstacles out of the work area.
Damage to property due to unintended rolling of the unit.
Place the unit on a level surface.
Lock the rollers’ brakes.
Storing the Unit
These storage conditions apply to the following:
New units
Units that were already in operation but will be temporarily out of operation. Refer to
Store the units as follows:
Completely drained of coolant to prevent possible damage due to freezing.
Dry, dust-free environment, protected against direct sunlight
According to required storage temperature and relative humidity. Refer to
Protection caps should be installed for the coolant inlet and outlet connections.
For storage that exceeds three months, it is recommended that the unit is placed inside its
original packaging.
Preparing the Unit for Further Transport
For detailed information and specific instructions on how to prepare the unit, refer to
NOTE
Risk of damage due to improper transportation
A coolant that has not been drained or packaging with inappropriate dimensions may cause
damage during transport.
Drain the coolant before transporting the unit. Refer to
Use proper packaging.
Transporting the Unit (after use)
Содержание Nextreme NRC1200 Series
Страница 1: ...Nextreme Recirculating Chiller Specification and User Manual Part Number 387004848 ...
Страница 17: ...17 Component Locations Figure 2 Isometric Views of Unit Figure 3 Top View ...
Страница 18: ...18 Figure 4 Front View Figure 5 Rear View Figure 6 Side View ...
Страница 37: ...37 Figure 21 Refrigerant Circuit and Coolant Circuit Figure 22 Coolant Circuit and Control Panel ...
Страница 39: ...39 Figure 25 Sensor Wiring Low Voltage ...
Страница 40: ...40 Plumbing Refrigeration Diagram Figure 26 Plumbing and Refrigeration Diagram ...
Страница 43: ...43 Figure 31 Pump Performance of NRC5000 with Cooling Fluids Water and 40 EG W ...
Страница 60: ...60 PCFLT Returns FLT fault or NO FAULTS FOUND PCFLT C Clears Fault Returns FLT Faults Cleared ...
Страница 69: ...69 Declaration of Conformity ...