90027911rev04
CHECKING NOMINAL HEAT CAPACITY
SAGB.... - SAGV.... - ARGS....
- Chamber Burner
Check the depth of the screw
“A”
in
accordance with
table 5
of the
“Tecnical gas
data”
booklet, using a gauge.
Check that the burner fan speed, corresponds
to the data given in
table 5
of the “Technical
gas data” booklet.
To enter the management screen of the burner to
check:
With the appliance live and display off, press
button
1
, the display
2
shows
[USb]
, turn knob
3
until
[rEL]
is displayed, press the knob to confirm
the selection
Turn knob
3
to set the password for parameter
modification and confirm by pressing knob
3
.
13 • OPERATING AT THE RATED HEAT OUTPUT