2 • TECHNICAL DATA
6
90027911rev04
TABLE 1: GENERAL DATA - ELECTRIC OVENS
Model
Supply
voltage
Frequency
(**)
Total power
imput
Amps
Chamber
power
Boiler
power
Motor
Oil-proof connection
cable ( * )
NAEB071.
SAEB071.
3N AC 400 V
3 AC 230 V
AC 230 V
50/60 Hz
10,5 kW
16
26
46
10 kW
7,5 kW
1 x 0,37 kW
5 x 2,5 mm
2
4 x 4 mm
2
3 x 10 mm
2
NAEV071.
AREN064.
SAEV071.
ARES064.
3N AC 400 V
3 AC 230 V
AC 230 V
50/60 Hz
10,5 kW
16
26
46
10 kW
-
1 x 0,37 kW
5 x 2,5 mm
2
4 x 4 mm
2
3 x 10 mm
2
NAEB101.
SAEB101.
3N AC 400 V
3 AC 230 V
50/60 Hz
16 kW
30
54
15 kW
15 kW
1 x 0,55 kW
5 x 4 mm
2
4 x 10 mm
2
NAEV101.
AREN084.
SAEV101.
ARES084.
3N AC 400 V
3 AC 230 V
50/60 Hz
16 kW
24
40
15 kW
-
1 x 0,55 kW
5 x 4 mm
2
4 x 10 mm
2
NAEB072.
SAEB072.
3N AC 400 V
3 AC 230 V
50/60 Hz
19 kW
34
60
18 kW
15 kW
1 x 0,55 kW
5 x 6 mm
2
4 x 10 mm
2
NAEV072.
SAEV072.
3N AC 400 V
3 AC 230 V
50/60 Hz
19 kW
30
49
18 kW
-
1 x 0,55 kW
5 x 6 mm
2
4 x 10 mm
2
NAEB102.
SAEB102.
3N AC 400 V
3 AC 230 V
50/60 Hz
31 kW
46
78
30 kW
30 kW
1 x 0,55 kW
5 x 10 mm
2
4 x 25 mm
2
NAEV102.
SAEV102.
3N AC 400 V
3 AC 230 V
50/60 Hz
31 kW
46
78
30 kW
-
1 x 0,55 kW
5 x 10 mm
2
4 x 25 mm
2
NAEB171.
SAEB171.
3N AC 400 V
3 AC 230 V
50/60 Hz
26,5 kW
46
80
10+15
kW
7,5 + 15
kW
0,37 + 0,55
kW
5 x 10 mm
2
4 x 25 mm
2
NAEM171.
SAEM171.
3N AC 400 V
3 AC 230 V
50/60 Hz
26,5 kW
46
80
10+15
kW
15 kW
0,37 + 0,55
kW
5 x 10 mm
2
4 x 25 mm
2
NAEV171.
AREN144.
SAEV171.
ARES144.
3N AC 400 V
3 AC 230 V
50/60 Hz
26,5 kW
40
66
10+15
kW
-
0,37 + 0,55
kW
5 x 10 mm
2
4 x 25 mm
2
NAEB201.
SAEB201.
3N AC 400 V
3 AC 230 V
50/60 Hz
31,8 kW
60
103
30 kW
30 kW
2 x 0,55 kW
5 x 10 mm
2
4 x 25 mm
2
NAEV201.
AREN154.
SAEV201.
ARES154.
3N AC 400 V
3 AC 230 V
50/60 Hz
31,8 kW
48
80
30 kW
-
2 x 0,55 kW
5 x 10 mm
2
4 x 25 mm
2
NAEB202.
SAEB202.
3N AC 400 V
3 AC 230 V
50/60 Hz
61,8 kW
92
155
60 kW
60 kW
2 x 0,55 kW
5 x 25 mm
2
2x (4 x 25 mm
2
)
NAEV202.
SAEV202.
3N AC 400 V
3 AC 230 V
50/60 Hz
61,8 kW
92
155
60 kW
-
2 x 0,55 kW
5 x 25 mm
2
2x (4 x 25 mm
2
)
Caution:
The residual current device to be installed between the mains and the appliance
must be sized for a leakage of 1 mA x kW of power installed.
( * ) Flexible cable underneath sheath resistant to oil with designation 60245-IEC-57
(**) for ovens compatible with operation at a frequency of 60 Hz, the data is the same. Always check the frequency shown
on the technical data label affixed to the appliance.
Содержание Naboo Series
Страница 2: ... 2 90027911rev04 ...