6 • ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING
6.1 •
As this oven is an appliance with a type Y
attachment, (oven without power cable
and plug), the cable and other hardware
needed to make the connection to the
electrical power supply must be provided
by the installer. The cable must satisfy the
requirements indicated in table 1
“General
data”
. As already mentioned, the oven must
be connected to the power supply by way of
a multiple pole main isolating switch ensuring
a gap between open contacts of at least 3
mm on each pole.
6.2 •
To gain access to the AC mains connection
terminal board, the right hand panel of the
casing must be removed by undoing the
fixing screws (all models).
6.3 •
The cable must be fed in from beneath the
clamp. The individual wires are then fastened
to the corresponding terminals of the terminal
board. The earth wire must be longer than the
other wires, so that in the event of the cable
being jerked or the clamp broken, the live
wires will disconnect first.
Check the efficiency of the isolating switch.
6.4 •
The oven must be kept in an equipotential
system. This connection is made by wiring a
conductor of nominal cross section 10 mm
2
to
the corresponding terminal at the back of the
oven, which is marked with the internationally
recognized symbol IEC60417 – 5021.
All appliances in the room are bonded in this
way and connected to the earth system of the
building.
6.5 •
The electrical safety of this appliance can
be guaranteed only when it is connected
correctly to an efficient earth system, in
compliance with current standards.
6.6 •
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order to
avoid a hazard.