Instruction LTC 11 Laing Innotech GmbH + Co. KG Althuette Germany
- 15 -
Connection of the motors
The motors must have an 8 pole Molex plug and must comply with the
requirements described under “Connectable motors”
The motors may then be plugged into the connectors of the controller. When
plugged in, the snap in pin will retain the plug. Make sure to press the snap in pin
when unplugging a motor to avoid damage to the controller.
The motors must be connected in the order shown on the controller cover.
Connection of the control panels and other control options
Control panels with cable
The control panels with cable must be plugged into the connector (5) of
the controller. Make sure that the plug is locked by the snap in. To unplug
the snap in pin must be pressed, not doing so may result in controller
damage!
Two control panels
The controllers can be controlled by two control panels. To do so the Y-
connector has to be used. The connections must be made as shown on
the picture. One connection is made to the controller, one to a control
panel with height indication, one to a control panel without height
indication.