For machines that are already assembled in your shop, follow the steps below to assemble the
crossbar to your unit for better and improved dust separation.
1.
Remove the drum and set aside to later connect back with unit.
2.
Loosen two of the bolts which are opposite each other that are connecting the drum lid to the
cyclone cone.
3.
The crossbar below is common for all models (CFLUX and PFLUX series and the TFLUX5).
4.
Take the crossbar and attach to the drum lid and tighten using the two bolts removed in the
previous step. It does not matter which position you attach the crossbar. As long as it does not
obstruct the sensor on the drum lid.
5.
Compelte the assembly by sliding your drum back in place.
CROSSBAR ASSEMBLY
TO IMPROVE PSYCLONIC SEPARATION
READ AND UNDERSTAND ALL WARNINGS AND OPERATING
INSTRUCTIONS BEFORE USING THIS EQUIPMENT. Failure to follow all instructions listed below,
may result in electric shock, fire, and/or serious personal injury or property damage.
Before removing any parts, turn OFF the machine and remove the power source.
PFLUX1 drum lid and crossbar
PFLUX2 drum lid and crossbar
Содержание C FLUX 1
Страница 1: ...Owner s Manual 1 5HP CYCLONE 1 Micron Canister lagunatools com lagunacleanair com supermaxtools com ...
Страница 4: ...RED BLACK Wiring ...
Страница 5: ...Wiring For 220V Conversion Aditional parts required CLFUX 1 220v Switch Assembly PDCCF15110 220V ...
Страница 36: ...1 5HP Mobile Dust Cyclone Manual 30 Step Thirty Three All the assembly steps have been completed ...
Страница 42: ...1 5HP Mobile Dust Cyclone Manual 36 2016 08 25 出圖章 山富機械公司 Parts Breakdown ...
Страница 43: ...1 5HP Mobile Dust Cyclone Manual 37 2016 08 25 出圖章 山富機械公司 SECTION A Close up view ...
Страница 44: ...1 5HP Mobile Dust Cyclone Manual 38 SECTION B Close up view ...
Страница 45: ...1 5HP Mobile Dust Cyclone Manual 39 SECTION C Close up view ...
Страница 46: ...1 5HP Mobile Dust Cyclone Manual 40 SECTION D Close up view ...
Страница 53: ......