Installing/Removing the Blade Guard
1. Un-plug the tablesaw!
2. Make sure the lock is in open position
3. Insert the blade guard
4. Position the guard insert
5. Lock the blade guard
6. Reinstall throat plate
CAUTION: Make sure the blade guard is in-
line with the blade. If it is not in line, please
see the Adjustments Section.
WARNING: MAKE SURE SAW IS UNPLUGGED.
With the throat plate removed, and the cam lock
mechanism in the open position (pulled up), insert
the blade guard insert into the slot.
Hold up the pawls and position the blade guard
against the left inside of the casing and push
down. Make sure the guard is positioned correctly
and seated in the bottom of the casing. Grasp the
pawls with one hand, leaving the other hand free
to activate the cam action lock.
Keep firm hold of the blade guard with left hand
and engage the cam lock with the thumb of your
right hand.
Grasp the pawls up and out of the way to re-insert
the throat plate. Lock the throat plate.
CAUTION: Make sure the riving knife is in-line with
the blade. If it is not in line, please see the
Adjustments Section.
Installing/Removing the Blade
1. Un-plug the tablesaw!
2. Remove any blade guards, riving knifes,
splitters, and the throat plate to access the
blade.
3. Set the arbor tilt to 0 degrees and lock.
4. Raise saw to highest position.
5. Engage blade lock (red component).
6. Remove the arbor nut and flange with
arbor wrench.
7. Remove or install blade.
CAUTION: Make sure the teeth of the blade
are facing the front of the saw as shown.
WARNING: MAKE SURE SAW IS UNPLUGGED.
To access the blade remove all accessories
around the blade, including riving knifes, throat
plates, ect.
Set the arbor tilt to 0 degrees and lock the arbor to
prevent it from moving when installing or removing
blades.
Raise the saw to the highest position to use the
red blade lock and arbor wrench to remove the
blade.
With the blade in the highest position, engage the
blade lock by pressing in with left thumb. Slowly
rotate blade to engage lock.
Grasp the pawls up and out of the way to re-insert
the throat plate. Lock the throat plate.
3. insert THE blade guard
4. position TO LEFT OF CASING
2. Remove all accessories
3. Set arbor tilt to 0 and lock.
4. Raise saw blade to highest pos.
6. Remove arbor nut and flange
5. Engage the blade lock
To front of saw
5. lock THE Blade Guard
6. Reinstall the throat plate
Содержание Fusion 3
Страница 28: ...Fusion Tablesaw 26 10 2017 Laguna Tools Inc Parts Diagrams Fence Assembly...
Страница 29: ...Fusion Tablesaw 10 2017 Laguna Tools Inc 27 Miter Gauge Blade Guard...
Страница 30: ...Fusion Tablesaw 28 10 2017 Laguna Tools Inc Motor and Trunnion...
Страница 31: ...Fusion Tablesaw 10 2017 Laguna Tools Inc 29 Cabinet...
Страница 32: ...Fusion Tablesaw 30 10 2017 Laguna Tools Inc F3 Cabinet...
Страница 37: ...Fusion Tablesaw 10 2017 Laguna Tools Inc 35 Notes...