MAINTENANCE - STORAGE - ASSISTANCE - DISPOSAL
Routine maintenance operations which can be performed by the user are described
below.
Have the machine repaired by qualified personnel only. This machine complies with all the
relevant safety prescriptions. Repairs to the machine must be carried out by skilled personnel
only using original spare parts. Failure to observe this recommendation could jeopardize user
safety.
BEFORE PERFORMING ANY MAINTENANCE WORK THE MACHINE MUST BE
DISCONNECTED FROM THE POWER SOURCE AND LOCKED OUT.
REPLACING SAW BLADE
Tools required: Appropriate hex keys and/or screwdrivers are needed to replace the blade.
Check the rotation of the used blade. Notice arrow direction on the head frame.
Use of used blades is not recommended.
Check the compatibility of the NEW blade for the saw. Only use a blade with a thickness
between .025” and .035”.
The characteristics of the blade must be compatible with the technical specifications.
The SE-5X6 RCT has reverse cutting technology and the teeth of the blade points forward
and rotates toward the front of the saw. If the blade is not welded for reverse cutting
technology, a standard blade that is reversed and inside out will also work. CAUTION
must be taken when reversing the blade and is not recommended for safety.
1. Loosen the blade guide handle and slide the blade guides towards the center of the of
the cutting head. Lightly tighten the handles
2. Remove the rear blade cover by unscrewing the 6 thumb screws. Remove cover and put
it safely out of your way.
WHEN THE BLADE COVER IS OPENED, THE BLADE MAY JUMP OUT.