![Lagoon 52 F Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/lagoon/52-f/52-f_user-manual_3306791131.webp)
SAFETY
129
11
SAFETY
z
PROCEDURE TO FOLLOW IN THE EVENT OF FIRE
- Turn off the engines if operating.
- Cut off the power supply, the fuel supply.
- Cut off all sources of air (smother the fire using blankets).
- Hold the extinguisher upright and aim at the heart of the fire.
If fire broke out in an engine hold:
- Turn off the engines if operating.
- Cut off the power supply, the fuel supply (handles located at the bot-
tom of the companionway to the forward port cabin and at the bottom
of the companionway to the starboard passageway) and gas supply if
required.
- Shut off the air supply using towels to block off the engine air inlets,
intakes and outlets.
- Spread the extinguishing product using the trigger mechanism of
the motor extinguisher. Starboard engine room: handle located in the
rear baseboard of the bed in the aft starboard cabin; port engine room:
handle located at the foot of the companionway to the aft port cabin.
- Make sure that the fire is completely under control.
- Open the bay access hatch to make any necessary repair.
z
ESSENTIAL PRUDENCE RULES
Never:
- Obstruct access to the emergency exits.
- Obstruct safety controls (fuel valves, gas valves, power switches).
- Obstruct the access to the extinguishers placed in cupboards or
lockers.
- Leave the boat unattended when a stove or heater is in use.
- Use gas lamps in the boat.
- Alter any of the boat’s systems (electricity, gas or fuel).
- Fill up a tank when an engine is running or a stove or heater is on.
- Smoke while handling fuels.
Make sure that engine holds are clean at all times and regularly check
that there are no fumes or fuel and gas leaks.
Do not store flammables products in the engine holds.
LAGOON 52 F
WARNING
Should you replace components of the fire extinction
system, only proper components with the same
designation or with equivalent technical capacities
and fire resistance should be used.
DANGER
Use CO2 extinguishers only to fight electrical fires.
Evacuate the area immediately after discharging the
product to prevent asphyxia.
Ventilate before entering.
DANGER
Always keep an extinguisher handy in case the fire
should start again.
Содержание 52 F
Страница 1: ...User s guide...
Страница 2: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 26: ......
Страница 28: ...DECK EQUIPMENT 26 HULL DECK LAGOON 52 F HULL PROTECTIONS...
Страница 40: ......
Страница 41: ...RIGGING SAILS 3 1 Sailing 3 2 Standing rigging 3 3 Running rigging 3 4 Sails 39 3...
Страница 56: ......
Страница 57: ...ACCOMMODATIONS 4 1 Saloon Galley 4 2 Lighting 4 3 Portholes Deck hatches 4 4 Window blinds 55 4...
Страница 62: ......
Страница 72: ......
Страница 82: ......
Страница 83: ...ELECTRICITY 7 1 12 V circuit 7 2 Inverters 7 3 110 V 220 V circuit 7 4 Electronics 81 7...
Страница 92: ...GENERAL BLOCK DIAGRAM 12 V 90 ELECTRICITY LAGOON 52 F...
Страница 96: ...STANDARD CIRCUIT EQUIPMENT 94 ELECTRICITY LAGOON 52 F INVERTER...
Страница 97: ...CHARGING CIRCUIT 220 V 12 V 95 7 ELECTRICITY LAGOON 52 F...
Страница 106: ......
Страница 107: ...MOTORIZATION 8 1 Engines 8 2 Fuel 8 3 Propellers Anodes 8 4 Optional controls 8 5 Bow thruster 105 8...
Страница 116: ......
Страница 117: ...WINTER STORAGE 9 1 Laying up 9 2 Protection 115 9...
Страница 118: ...PACKING 116 WINTER STORAGE LAGOON 52 F 6000 mm 8744 mm 15839 mm 6809 mm 4227 mm 1505 mm 2768 mm...
Страница 120: ......
Страница 121: ...HANDLING 10 1 Preparation 10 2 Crane lifting 10 3 Mast stepping Mast unstepping 119 10...
Страница 122: ...DIMENSIONS FOR CRADLE POSITIONING 120 HANDLING LAGOON 52 F 2612 5 mm 9312 5 mm...
Страница 124: ......
Страница 126: ...124 SAFETY LAGOON 52 F...
Страница 136: ......
Страница 137: ...MAINTENANCE 135 12...
Страница 140: ......
Страница 142: ......
Страница 143: ......
Страница 144: ...UPDATED 01 2016...