LaCie Biggest S2S
User Manual
page 0
Front Panel LED Indicators
Each disk drive and the host connection have two
LEDs to indicate drive status and/or host communica-
tion status, see Figure 2. LED 0 is on the left, and is
typically blue; LED 1 is on the right and is typically
green.
Additionally, there are two error-condition lights
that are available for troubleshooting.
When the LaCie Biggest S2S is powered on, the
•
host scans the disks in sequence, as indicated by a
brief flash of lights on LED 1. Once the host scan
is complete, LED 1 is lit for each drive present.
During disk operations, LED 0 flashes as data is
transferred to and from the drive and the host. If a
Safe volume is being rebuilt, LED 1 blinks slowly
on both mirrored disks.
•
7. LaCie Biggest S2S Front Panel LED Indicators
LED O
LED 1
! LED
OK LED
!
OK
Description
Off
On
Startup or ON indication.
OK LED will flash during
reset and will remain green in
all other cases.
On
Error
The “!” LED will light as a
result of an EEPROM error
during boot or following a
run time error.
LED 0
LED 1
Description
Off
Off
Power On, No device at-
tached
Off
On
PHY communication estab-
lished, (Activity = LED0 On)
On
Blink
Rebuild
Blink
Blink
Error