background image

                                                                                                                                                                               

 

 

 

Axius                                                         Part No: 6137120-795   

Issue: 1.0                                    
Printed On: June 10, 2023 

 

 

Axius 

     User Instructions 

(continued)

 

 

2.3.  Terms and Conditions of warranty 

  Labomed provides the final customer with a warranty that the product cited in the handover 

certificate will function properly and guarantees zero defects in the material or processing for a 
period of 12 months from data of purchase, subject to the following conditions: 

  Upon justified complaints of flaws or a short delivery, Labomed will make good its warranty by 

replacing the product free of cost or repairing it according to the customer's wishes. Other 
claims of any nature whatsoever, in particular with respect to compensation, are excluded. In 
the event of default and gross negligence or intent, this shall only apply in the absence of 
mandatory legal regulations to the contrary. 

  Labomed cannot be held liable for defects and their consequences due to natural wear, improper 

cleaning or servicing, non-compliance with operating, servicing or connection instructions, 
calcification or corrosion, contaminated air or water supplies or chemical or electrical factors 
deemed abnormal or impermissible in accordance with factory specifications. 

  The warranty does not usually cover bulbs, glassware, rubber parts and the colourfastness of 

plastics. 

  Defects or their consequences that can be attributed to interventions on or changes made to the 

product by the customer or a third party are excluded from the warranty. 

  Claims from this warranty can only be asserted when the transfer form (copy) belonging to the 

product has been sent to Labomed, and the original can be presented by the operator or user. 

   

2.4  Transportation and storage 

   
 Note 

 

Labomed shall not be held liable for damage arising from transportation. The shipment must be 
checked on arrival. 

   
  If the packing is visibly damaged on delivery, please proceed as follows: 

1.  The recipient of the package must record the loss or damage on the delivery receipt. The 

recipient and the representative of the shipping company must sign this delivery receipt. 
Without this evidence, the recipient will not be able to assert a claim for damages against the 
shipping company. 

2.  Leave the product and packaging in the condition in which you received it. 
3.  Do not use the product. 

   
  If the product is damaged but there was no discern able damage to the packaging on delivery, 

proceed as follows: 

1.  Report any damage to the shipping company immediately and no later than 7 days after 

delivery. 

2.  Leave the product and packaging in the condition in which you received it. 

 

    

 

 

 

Содержание AXIUS

Страница 1: ...ssue 1 0 Printed On June 10 2023 AXIUS Centre Pole User Manual To ensure proper use of this instrument as well as to avoid injury while operating instrument Understanding this manual completely before...

Страница 2: ...to change without prior notice LABOMED reserve the right to make changes to the product described in this user manual without notice and without incorporating those changes in any products already sol...

Страница 3: ...tions 8 3 1 1 Warning symbol 8 3 1 2 Structure 8 3 1 3 Description of Hazard levels 8 3 2 Safety Inctructions 9 4 Product description 10 4 1 Intended use Proper use Indications for use 11 4 2 Scope of...

Страница 4: ...ows comfortable use over a long period Salient features of Axius are 1 Axius carries all important equipments like X Rays Monitor Light Trays Microscope 2 Axius allows each Equipment s comfortable use...

Страница 5: ...technical Commision RI Repair instructions EMC Electromagnetic compatibility PI Processing instructions 2 1 2 Symbols See Section on Hazard levels Important information for users and technicians CE ma...

Страница 6: ...ications The warranty does not usually cover bulbs glassware rubber parts and the colourfastness of plastics Defects or their consequences that can be attributed to interventions on or changes made to...

Страница 7: ...instrument or has become illegible please contact the manufacturer to obtain new labels Caution label Observe all caution notes to avoid any unwanted situation with the instrument Accompanying docume...

Страница 8: ...es 4 units of 3 7 m length each Package 3 Accessories 2 6 Disposal Note Any waste which is generated must be recycled or disposed of in strict compliance with all applicable national regulations in a...

Страница 9: ...ing between three hazard levels are used in this document to prevent personal and property damage The warning and safety notes in this document must be observed to prevent personal injury and material...

Страница 10: ...the attached device while safeguarding the cables from damage On principle there must not be any electrical insulating points inside the AXIUS Column The cables routed in the AXIUS Column must be equ...

Страница 11: ...o Microscope adapter Prima 6137160 800 Microscope adapter Magna 6129002 805 OT light kit 6137160 860 Operating light adapter 6137160 863 Operating light arm 6137160 862 X Ray arm kit 6137160 875 X ray...

Страница 12: ...h Intended use also comprises the observation of all indications in the instructions for used as well as adherence to prescribed inspections and maintenance Electrically supplied accessory devices mus...

Страница 13: ...tinued Axius 0 000 0000 2023 05 00000000 Labotech Microscopes India Pvt Ltd 19 HSIIDC Industrial Estate Ambala Cantt 133 006 Haryana INDIA LABOMED Type Device type SN Year of Manufacture Serial number...

Страница 14: ...nd drill Align the two notches on the inner diameter of the mounting plate 6137160 102 see floor plan section A A parallel to the middle axis of the patient chair Note The curved oblong holes in this...

Страница 15: ...maximum deviation from the vertical 1 mm per 1 m of height Align the column with the four fastening nuts and the four counter nuts Check the alignment with a spirit level Finally tighten all nuts and...

Страница 16: ...m and saw it out If the distance between ceiling and false ceiling is large in the area in which you work disassemble the false ceiling elements to provide for freedom of movement during the installat...

Страница 17: ...tion from the vertical 1 mm per 1 m of height In the presence of a false ceiling the support plate is to be installed on the profile piece using 2 cheese head screws M5x12 and 2 rhomboid T slot nuts M...

Страница 18: ...0 Printed On June 10 2023 Axius Installation continued 5 3 3 Mounting the column B False ceiling at the level of the pull out rod 4 Profile piece 6137160 116 5 Allen screws SS 188 C False ceiling at t...

Страница 19: ...Microscope adapter 6137160 800 Adapters kits for support arms are available for the following units OT light kit 6137160 860 Xray arm kit 6137160 874 Laptop arm kit 6137160 867 Monitor arm kit 613716...

Страница 20: ...ting plate s at the top of the column profile and position and tighten them at the desired height as requested by the customer User spirit level to align the support arms during the assembly on the co...

Страница 21: ...onitor arm 6137160 122 as ordered onto the mounting bracket in the support arm receptacle using the screw SS 898 as shown 3 Fix the Mounting Adapter 6137160 801 of Microscope as ordered with fixed sha...

Страница 22: ...for all screws of size M8 or larger is 10 Nm Screws situated on the inside can be tightened using an Allen key or an open ended spanner SW 6 mm CAUTION Overload Damage and injury The maximal load of...

Страница 23: ...size according to the onsite conditions and snap them in Note Cover the saw cuts on the ceiling and floor fastening by approximately 30 mm and on the arm systems by approximately 2 mm Snap in the arm...

Страница 24: ...extent that the recesses provided in the cover can be pushed firmly over the screw heads You might need to create a small recess in the cover at this site in order to be able to tighten down the coun...

Страница 25: ...eiling Using the Paper template provided mark the positions of the three mounting holes on wooden membrane Drill three 1 4 6mm pilot holes either direct into Joist or the additional wooden membrane as...

Страница 26: ...xius Installation continued Floor Plans 2400 3900 660 1900 2512 1675 320 620 900 25 On consultation with the dentist measurement A can be increased by amount B if required The measurement of 550 mm in...

Страница 27: ...l safety check according to IEC 62353 DIN VDE 0751 1 Perform the general functional tests Note For information regarding the operation of the devices please refer to the respective Instructions for Us...

Страница 28: ...t 6137160 860 Operating light adapter 6137160 863 Operating light arm 6137160 862 X Ray arm kit 6137160 874 X ray arm 6137160 871 X Ray arm adapter 6137160 872 X Ray unit kit 6137160 875 X ray unit 61...

Отзывы: