Axius Part No: 6137120-795
Issue: 1.0
Printed On: June 10, 2023
Axius
Installation
(continued)
Note
In an installation in the presence of a false ceiling, the direction of the fastening straps of the ceiling
plate can be selected freely.
Remove the four wedges again and drive the tube into the column.
Now drill the holes on the ceiling.
If the ceiling has no false ceiling, screw the supporting plate
③
to the ceiling plate on the
ceiling.
Note
Compensate for uneven surfaces on the ceiling with the nuts
⑩
.
Re-attach the four wedges such that the column stands upright. Screw the threaded pins
⑩
(M6 x 8) into the threaded holes of the aluminium column profile
⑥
to the stop in
order to support the pull-out rod
⑫
. Check with a spirit level.
CAUTION
Deviation from vertical
Damage and injury
Do not exceed a maximum deviation from the vertical - 1 mm per 1 m of height.
In the presence of a false ceiling, the support plate
⑥
is to be installed on the profile piece
⑦
using 2 cheese-head screws M5x12 and 2 rhomboid T-slot nuts M5 or directly to the
column (see Fig.).
This profile piece is then slid upwards on the equaliser rod until the wings of the support
plate touch the false ceiling. Align the profile piece appropriately such that one of the three
wings of the intermediary plate
②
points in the 3 o'clock position while the profile piece is
aligned with the profile of the column.
Use the threaded pin M6x10 to clamp the clamping washer
⑧
to the equaliser rod directly
below.
The cladding profiles must be sawed off properly such as to end just below the support plate.
In rooms with no false ceiling, the one or two profile pieces
⑦
must be placed on the upright
support such that the cladding profiles are optimally supported.
A without false ceiling
1.
Cover 6137160-202
2.
Ceiling plate
6137160-104
3.
Support plate
6137160-305
16