4.
Settings
The settings of the idOil unit can be changed with the text message commands described in
the following paragraphs.
4.1.
Mobile numbers
Up to five telephone numbers can be programmed in the device, to which the unit can then
send alarm messages and from which it can receive settings and alarm status queries.
This setting can also be entered via the idOil unit’s browser user interface.
4.1.1. Setting telephone numbers and telephone number queries (TEL)
A total maximum of five numbers can be set 1–5 numbers at a time. The number is always
saved in the first free memory slot.
The format of the telephone number setting command is:
TEL <no1> <no2> <no3> <no4> <no5>
Field legend
TEL
Telephone number setting command
<no1> <no2> <no3> <no4> <no5>
End user telephone numbers in international
format delineated with spaces.
The device responds with a message including the name of the device (if set), the set
telephone numbers and the corresponding memory slots in the device memory.
TEL <device name if specified>
1: <memory slot 1 telephone no>
.
.
5: <memory slot 5 telephone no>
Example:
If the device name has not been defined, no numbers have been set and the entered
command is
TEL. +358403584035840333333
the response is:
TEL
1: +35840111111
2: +35840222222
3: +35840333333
If, after this, the command
TEL +35840444444
is entered, the response is:
TEL
1: +35840111111
2: +35840222222
3: +35840333333
4: +35840444444