6
DISPLAY CONTRAST
‐
This
adjusts
the
display
contrast.
This
value
can
be
set
from
0
to
50.
CPU VERSION AND DATE
‐
This
displays
the
CPU
version
number
and
the
date
of
the
software.
This
is
informational
only,
these
items
cannot
be
changed.
ADVANCED
LEVEL
EXTEND AIR ASSIST
‐
This
setting
determines
the
amount
of
time
that
air
assist
remains
on
after
the
end
of
label
feed.
This
value
can
be
set
from
1
to
999
milliseconds.
TAMP BACK AFTER AIR BLOW
‐
When
set
to
YES
,
the
tamp
will
retract
at
the
end
of
air
blast.
When
set
to
NO
,
the
tamp
will
retract
at
the
beginning
of
air
blast.
This
menu
item
is
only
available
when
TAMP BLOW
is
set
to
YES
in
the
Service
Menu.
DUAL TAMP MODE
‐
When
set
to
YES
,
the
tamp
will
extend
and
retract,
then
the
swing
mechanism
will
extend
and
retract.
When
set
to
NO
,
the
tamp
will
extend
and
retract
in
a
single
motion.
TAMP SETTLE TIME
‐
When
the
tamp
is
retracted,
the
amount
of
time
that
will
elapse
before
it
is
capable
of
applying
a
new
label.
SWING TAMP FIRST
‐
When
DUAL TAMP MODE
is
set
to
YES
,
setting
this
to
YES
,
will
activate
the
swing
tamp
function
first,
and
NO
will
activate
the
side
tamp
first.
When
DUAL TAMP MODE
is
set
to
NO
,
setting
this
to
YES
will
activate
the
swing
tamp
only;
Setting
this
to
NO
will
activate
the
side
tamp
only.
SWING TAMP INVERTED
‐
Available
only
when
DUAL TAMP MODE
is
set
to
YES
.
Set
this
to
YES
for
Inverted
Swing
Tamp
operation,
or
to
NO
for
Tamp
Blow
Swing
Tamp
operation.
SWING TAMP EXTEND TIME
‐
Available
only
when
DUAL TAMP MODE
is
set
to
YES
.
This
tells
the
microprocessor
the
amount
of
time
in
milliseconds
it
takes
the
swing
tamp
to
move
from
the
retracted
position
to
the
extended
position.
This
is
required
for
the
Air
Blast
to
occur
at
the
right
time.
This
value
can
be
set
from
1
to
3000
milliseconds.
SWING TAMP RETRACT TIME
‐
Available
only
when
DUAL TAMP MODE
is
set
to
YES
.
This
tells
the
microprocessor
the
amount
of
time
in
milliseconds
it
takes
the
swing
tamp
to
move
from
the
extended
position
to
the
retracted
position.
This
is
required
for
the
label
feed
to
begin
at
the
right
time.
This
value
can
be
set
from
1
to
3000
milliseconds.
SWING TAMP AIR BLAST DWELL
‐
Available
only
when
DUAL TAMP MODE
is
set
to
YES
.
This
sets
the
duration
of
the
air
blast
for
the
swing
tamp.
This
value
can
be
set
from
1
to
999
milliseconds.