44
SIDE TAMP ADJUSTMENT
The
tamp
pressure
and
flow
controls
were
set
at
the
factory.
Use
the
following
instructions
to
check
the
tamp
function
and
to
make
adjustments
if
necessary.
1.
Set
the
side
tamp
air
pressure
regulator
to
60
P.S.I.
(4.0
bar).
2.
Disable
the
tamp.
3.
From
the
Advanced
menu,
use
the
[up/down]
arrows
to
select
side
tamp
extend
time.
4.
Press
the
[FEED]
key
to
cycle
the
side
tamp
several
times
and
observe
the
tamp
action.
The
side
tamp
should
move
quickly
and
smoothly
without
slamming
to
a
stop
at
either
end
of
travel.
If
the
tamp
functions
properly,
leave
the
[TAMP]
IN
Disable
mode
and
press
the
[enter]
button.
If
the
tamp
does
not
move
quickly
and
smoothly,
or
if
it
slams
to
a
stop
at
either
end
of
travel,
continue
with
step
5.
5.
Locate
the
side
tamp
flow
controls
located
on
the
tamp
support
assembly.
6.
Loosen
the
side
tamp
flow
control
lock
nuts
with
a
3/8
inch
open
end
wrench.
7.
Press
the
[feed]
button
to
cycle
the
side
tamp
and:
A
Adjust
the
thumbscrew
on
the
extend
flow
control
until
the
side
tamp
extends
quickly,
but
does
not
crash
to
a
stop;
and
B
Adjust
the
thumbscrew
on
the
retract
flow
control
until
the
side
tamp
retracts
quickly,
but
does
not
crash
to
a
stop.