20
3.
Position
the
lead
edge
of
a
product
at
product
detector
#1(stop
conveyor).
See
figure
XX.
4.
Set
the
swing
tamp
air
regulator
to
zero.
5.
Manually
extend
the
swing
tamp.
Measure
the
distance
from
Product
Detector
#1
to
the
fully
extended
swing
tamps.
Record
the
distance
"X".
See
Figure
8.
6.
If
the
conveyor
is
running
at
45
feet
per
minute,
the
conveyor
is
running
at
approximately
9
inches
per
second.
If
the
conveyor
is
running
at
15
meters
per
minute,
the
conveyor
is
running
at
approximately
0.25
meters
per
second.
NOTE:
If
the
conveyor
is
running
at
some
different
speed,
determine
how
far
the
conveyor
travels
in
one
second.
7.
Divide
the
distance
"X"
by
the
conveyor
speed
per
second.
The
resulting
number
is
the
approximate
LABEL
ON
PRODUCT
POSITION.
Use
the
[UP]
and
the
[DOWN]
buttons
to
set
the
LABEL
ON
PRODUCT
POSITION
to
slightly
less
than
the
calculated
number.
8.
Set
the
swing
tamp
air
regulator
to
60
P.S.I.
(40
bar).
9.
Manually
apply
a
label
at
the
required
position
on
the
side
of
the
product.
10.
Position
the
lead
edge
of
the
product
at
product
detector
#2
(stop
conveyor).
See
figure
9.
11.
Refer
to
Figures
10.
Measure
the
distance
between
the
downstream
edge
of
the
label
on
the
side
of
the
product
and
the
downstream
edge
of
the
tamp
pad.
Record
the
distance
"Y".
12.
Divide
distance
"Y"
by
the
conveyor
speed
per
second.
The
resulting
number
is
the
approximate
SECOND
LABEL
POSITION.
Use
the
[UP]
and
[down]
keys
to
set
the
second
label
on
position
to
the
calculated
number.