12
1. Press the [custom] button till tamp is disable appears on the screen.
2. Position product detector #1 at an appropriate position relative to the extended swing tamp.
Product Detector #2 can be downstream of the retracted side tamp if the label is applied further
towards the trailing end of the product.
3.
Position Product Detector #2 at an appropriate position relative to the retracted side tamp and
downstream from Product Detector # 1.
SIDE AND REAR APPLI CATOR
Product Detector #1 should be positioned upstream
3
of the retracted side tamp. Product Detector
#1 must be positioned far enough upstream to allow the side tamp time to reach the fully
extended position, or the side of the product, as the product arrives at the apply position. See
Figure 2.
When using two product detectors, product Detector #2 must be positioned downstream of
Product Detector #1 and must be positioned far enough upstream to allow the swing tamp time to
reach the fully extended position as the product arrives at the apply position. See Figure 2.
Figure
2
Figure 2 Product Detectors #1 and #2 Side and Rear Application