background image

Page 26

LAARS Heating Systems

6.6.2 Alarm Acknowledge

When an alarm is activated (LO or one of the F

codes), the control will flash between the alarm

display and the supply temperature. Pressing the

power button (upper left button) for half a second will

allow the user to scroll through the menus for 30

seconds, before reverting back to the alarm display.

6.6.3 Power On/Off

Pressing the power button on the control (upper

left button) for 3 seconds will turn the controller off.

This will not de-energize the boiler’s power, but will

de-energize the controller. The display will still work,

but the boiler will not acknowledge a call for heat, and

will not be able to fire. This allows the user to check

and set parameters when the boiler is unable to fire.

The display will show “OFF”. When the power button

is pressed again for 3 seconds, the display will show

“ON” briefly, and the boiler will then resume normal

operation.

6.6.4 Low Fire Hold

By pressing and holding the enter button and the

down arrow button for 2 seconds, the user will fix the

Endurance in low fire for 5 minutes. There is no

change in the boiler control display when the unit is in

this mode.

6.6.5 High Fire Hold

By pressing and holding the enter button and the

up arrow button for 2 seconds, the user will fix the

Endurance in high fire for 5 minutes. This can be used

to check and/or set combustion on the appliance.

There is no change in the boiler control display when

the unit is in this mode.

6.6.6 Pump Operation

The Endurance’s internal pump will operate

when any of the following conditions occur:

Low temperature mode.

Tank charge mode.

Heating system (T-T) call for heat.

Domestic hot water (DHW) call for heat.

Error condition detected.

Supply temperature detected as less than

“boiler on point”.

6.6.7 Anti-Condense Valve Operation

The control on the EBP unit opens and closes the

Anti-Condensing Valve (ACV) based on the following

boiler conditions:

ACV Open:

Heating system (T-T) call for heat, when

there is no tank charge or DHW call for

heat.

Cycles open and then closes every time the

EBP is powered up.

ACV Closed:

 Domestic hot water (DHW) call for heat.

Tank charge mode.

No heating system (T-T) call for heat.

Button

Action

Result

Up Arrow

Press for 1/2 second

1. Scrolls up through view menu

(Upper Right Button)

2. In setup menu, scrolls up through setup menu
3. In setup menu, after parameter is chosen, increases

 the value of that parameter

Down Arrow

Press for 1/2 second

1. Scrolls down through view menu

(Lower Right Button)

2. In setup menu, scrolls down through setup menu
3. In setup menu, after parameter is chosen, decreases

the value of that parameter

Enter

Press and hold for 3 seconds

Puts the control is setup mode

(Lower Left Button)
Enter

Press for 1/2 second

1. When in setup view, chooses the parameter that the

(Lower Left Button)

user wants to adjust
2. When in setup menu, saves an adjusted parameter

Enter & Up Arrow Together

Press both together for 2 seconds

High fire hold for 5 minutes

(Lower Left and Upper
Right Buttons  Together)
Enter & Down Arrow Together

Press both together for 2 seconds

Low fire hold for 5 minutes

(Lower Left and Lower Right
Buttons  Together)
Power

Press for 1/2 second

When in alarm mode, allows the user to scroll through

(Upper Left Button)

menu for 30 seconds

Power

Press and hold for 3 seconds

Turns control off or on to allow programming without a

(Upper Left Button)

call for heat interruption.

Table 4.  Boiler Control Button Functions.

Содержание EBP0110

Страница 1: ...llation and maintenance Improper installation and or operation could create carbon monoxide gas in flue gases which could cause serious injury property damage or death Improper installation and or ope...

Страница 2: ...elay 24 6 4 4 Oar Outdoor Reset 24 6 4 5 Oal Minimum Outdoor Reset Point 25 6 4 6 rc Outdoor Reset Ratio 25 6 4 7 oTo Warm Outdoor Shutdown 25 6 4 8 unl Temperature Units 25 6 4 9 Add Control Address...

Страница 3: ...with the gas to the burner flame holder Both the intake air and the gas are metered through separate orifices before entering the combustion air blower The blower forces the air fuel mixture through t...

Страница 4: ...rain etc during appliance operation or service circulator replacement control replacement etc 1 5 Clearances The dimension and criteria in Table 1 should be followed when choosing the location for the...

Страница 5: ...ate the opening centerline 16 1 2 42cm above grade use optional concentric vent terminal extension part number 2400 428 shown in Figure 7 In the U S vent terminals must be at least 3 feet 0 9m above a...

Страница 6: ...rements are from the centerlineof the venting to the boiler top or face of outside wall Dimensions shown in inches Configuration 2 Maximum horizontal 38 Maximum vertical 16 Measurements are from the c...

Страница 7: ...Endurance Page 7 Figure 7 Concentric Vent Parts Dimensions shown in inches...

Страница 8: ...tlet See note 4 3 feet 91 cm J Clearance to nonmechanical air supply Direct Vent Only 12 inches 30 cm inlet to building or the combustion air inlet Other Than Direct Vent 4 feet 1 2 m below or 36 inch...

Страница 9: ...atFab Inc under the trade name of Saf T Vent by Z Flex under the trade name of Z Vent and by ProTech Systems Inc under the trade name FasNSeal Follow the special gas vent manufacturer s instructions r...

Страница 10: ...Page 10 LAARS Heating Systems Figure 13 3 Vent Parts Dimensions shown in inches...

Страница 11: ...r boilers that are getting all of their combustion air from inside the building The confined space shall be provided with two permanent openings communicating directly with other spaces of sufficient...

Страница 12: ...reen can be used One portion of this assembly connects to the 5 air collar with a screen for the combustion air and the other part connects to the 3 flue opening see Figure 14 The rest of the 3 vent s...

Страница 13: ...ocal requirements 3 Install drip leg ground joint union and drip cap to trap sediment and for test gauge access 4 Support all piping with proper hangers 5 All threaded joints should be coated with pip...

Страница 14: ...e domestic potable water temperature has fallen below 39 4 C If this condition is recognized the Endurance pump will run for 5 minutes or until the boiler water temperature reaches 45 F 7 C If the boi...

Страница 15: ...Endurance Page 15 Figure 19 Hydronic Piping EDP EBP with Zone Valves Figure 20 Piping Single EDP EBP Boiler for Multiple Temperature Systems Figure 21 Piping Model EDP EDN for Radiant Floor...

Страница 16: ...Install an air purger in flow supply line as shown in piping diagrams 5 Install automatic float type air vent on air scoops Figure 22 Hydronic Piping EBP EDP for Systems Zoned with Circulators Figure...

Страница 17: ...ipped with a Low Temperature control feature that recognizes when the water temperature at the outlet of the boiler has fallen below 39 F 4 C If this condition is recognized the Endurance pump will ru...

Страница 18: ...y hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS D...

Страница 19: ...s il n y a pas d odeur de gaz pr s du plancher car le gaz est plus lourd que l air et peut se d poser sur le plancher QUE FAIRE EN CAS D ODEUR DE GAZ N essayez pas d allumer n importe quelque apparei...

Страница 20: ...tch Neutral leg to white wire Ground wire can be connected to the grounding screw in the box or on the switch 2 For single zone installations If external pump is required e g because of large system p...

Страница 21: ...Clock Thermostats That Require 24 VAC RELAY 24 VOLT NO CONTACT LAARS P N 2400 060 TO T T BOILER CONNECTIONS 120V 24 20VA W Y G R Rc L1 HOT L2 120 VAC TRANSFORMER NOTE This wiring required only for sin...

Страница 22: ...rner On Point that is calculated by subtracting the Burner On Differential from the Burner Control Point The Burner On Differential is adjustable from 4 to 30 F 2 to 17 C in the EDP EDN models and is...

Страница 23: ...ic Example Figure 32 EDP EDN Flow Schematic 6 Calculated Setpoint for Outdoor Reset shown as CSP when used The temperature that the controller has calculated for a setpoint based on the outdoor temper...

Страница 24: ...This parameter shown as PO in the selection screen allows the user to choose between the Endurance pump running continuously Con or running in the automatic mode Aut such that the pump is energized on...

Страница 25: ...ach of the buttons 6 4 5 Oal Minimum Outdoor Reset Point The Oal parameter tells the controller what the minimum allowable supply temperature can be regardless of the outdoor reset calculation For EDP...

Страница 26: ...g system T T call for heat Domestic hot water DHW call for heat Error condition detected Supply temperature detected as less than boiler on point 6 6 7 Anti Condense Valve Operation The control on the...

Страница 27: ...etween the space in which the appliances remaining connected to the common venting system are located and other spaces of the building Turn on clothes dryers and any appliance not connected to the com...

Страница 28: ...en all supply and return valves 2 Fill heating system to minimum operating pressure 12 psig 3 Loosen screw in coin vent and allow any trapped air to escape Collect any water that escapes so that it do...

Страница 29: ...l properly If a pump change is required for any reason valve off the boiler and drain approximately 1 or 2 gallons approx 4 8L of water from it Turn off the main disconnect switch and unplug the pump...

Страница 30: ...acing shut off the 120 volt power Unplug the transformer wires from the transformer unscrew the two fixing screws and remove the transformer Fit the replacement transformer in reverse order 8 8 PWM Bo...

Страница 31: ...om gas valve flange Unplug the blower and the ignitor Remove the bolts from the blower and pull the blower out The boiler assembly may now be removed from the jacket After removal of the boiler assemb...

Страница 32: ...WIRING 24V 115V G Y GREEN WITH YELLOW V VIOLET GR GRAY G GREEN O ORANGE BR BROWN BL BLUE Y YELLOW R RED W WHITE BK BLACK COLOUR LEGEND FACTORY WIRING BL W BL W G LINE CONN GND MV1 W S2 FS L2 L1 S1 120...

Страница 33: ...durance in setpoint mode instead of outdoor reset mode The ignition control uses LED indication to display the following fault codes Steady On Internal control failure 2 Flashes Erroneous flame signal...

Страница 34: ...o disconnect anything to measure the flame current signal To measure the flame signal connect an analog DC microammeter to the FC terminals on the ignition control per Figure 37 The meter should read...

Страница 35: ...range adjust the gas valve calibration Always adjust the air orifice first To adjust the gas valve calibration see figure 35 for the location of the offset pressure port and the offset adjustment Whe...

Страница 36: ...ct install a smaller gas orifice so that the O2 will rise above 4 or the CO2 will drop to 8 natural or 9 LP The CO2 O2 readings may be influenced by cross contamination Suspect cross contamination if...

Страница 37: ...ons of minerals in the water These minerals may cause fouling of the DHW heat exchanger over an extended period of time lime build up Other minerals which react more quickly in well systems mostly mag...

Страница 38: ...Repair Kit 2400 538 2400 538 16 Anti Condensing Valve Operator Only 2400 539 2400 539 17 Water Flow Switch 2400 542 2400 542 18 Safety Limit 230 F 2400 550 2400 550 2400 550 2400 550 2400 550 2400 55...

Страница 39: ...Endurance Page 39...

Страница 40: ...x 800 559 1583 Customer Service Service Advisors 20 Industrial Way Rochester NH 03867 603 335 6300 Fax 603 335 3355 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 0130 ww...

Отзывы: