Premier Ductable Heaters
www.lbwhite.com
Owner’s Manual • Premier 80-170
24
Service Instructions
1. Close the fuel supply valve to the heater
and disconnect the electrical supply before
servicing unless necessary for your service
procedure.
2. Clean the heater’s ori
fi
ce with compressed
air or a soft, dry rag. Do not use
fi
les, drills,
broaches, etc. to clean the ori
fi
ce hole.
Doing so will enlarge the hole, causing
combustion or ignition problems. Replace
the ori
fi
ce if it cannot be cleaned properly.
3. The high limit switch can be tested by:
-- Disconnecting the leads at the compo-
nent, and jumpering the leads together.:
-- Reconnect the electrical supply and open
fuel supply valves.
-- If the heater lights, the component is
defective and must be replaced.
-- Do not leave the jumper on or operate the
heater if the part is defective. Replace the
part immediately.
-- An alternate method for checking the
components is to perform a continuity
check.
WARNING
Burn Hazard
■
Heater surfaces are hot for a period of time after
the heater has been shut down.
■
Allow the heater to cool before performing
service, maintenance, or cleaning.
■
Failure to follow this warning will result in burns
causing injury.
WARNING
Fire and Explosion Hazard
■
Do not disassemble or attempt to repair any
heater components or gas train components
such as gas valves, or gas hoses.
■
All component parts must be replaced if defects
are found.
■
Failure to follow this warning will result in
fi
re or
explosions, causing property damage, injury, or
death.
Motor & Fan Assembly
1. Open louvered access panel opposite the
burner end of heater. Disconnect motor leads.
2. Remove all screws securing the motor mounting
plate to the housing.
3. Pull the fan and motor assembly from the
housing.
4. Loosen set screws on fan wheel.
5. Pull the fan wheel from motor shaft.
6. Remove the four nuts securing motor to
mounting plate.
FIG. 22
Motor Mount Plate
Screws
4. The air proving switch must not be jumpered. If
jumpered, the ignition control will not allow heater
operation. Test the air proving switch for continu-
ity. If defective, replace the switch.
5. Open the respective case panel for access to
burner or fan related components. Open the
control box for access to the ignition controller,
and transformer.
6. Disconnect the appropriate electrical leads when
replacing components.
7. For reassembly, reverse the respective service
procedure. Ensure gas connections are tightened
securely and leak checked.
8. After servicing, start the heater to ensure proper
operation.
Содержание Premier 80
Страница 40: ...Premier Ductable Heaters www lbwhite com Owner s Manual Premier 80 170 40...
Страница 43: ...Premier Ductable Heaters Owner s Manual Premier 80 170 43 Service Parts Identification Schematic...
Страница 46: ...Premier Ductable Heaters www lbwhite com Owner s Manual Premier 80 170 46 Notes...
Страница 87: ...Calefactores canalizados Premier www lbwhite com Manual del usuario Premier 80 170 40...
Страница 93: ...Calefactores canalizados Premier www lbwhite com Manual del usuario Premier 80 170 46 Notas...
Страница 134: ...Fournaises Premier gainables www lbwhite com Manuel du propri taire Premier 80 170 40...
Страница 137: ...Fournaises Premier gainables Manuel du propri taire Premier 80 170 43 Sch mas d identification des pi ces de rechange...
Страница 140: ...Fournaises Premier gainables www lbwhite com Manuel du propri taire Premier 80 170 46 Remarques...