Bloom 400 Greenhouse Heater
www.lbwhite.com
Owner’s Manual • Bloom 400
16
WARNING
This heater must not be washed. Use of a pressure
washer, water, or liquid cleaning solution on the control
components can cause severe personal injury or property
damage due to water and/or liquids:
■ In electrical components, and wires causing electrical
shock or equipment failure.
■ On gas control valves causing corrosion which can
result in gas leaks and fire or explosion from the leak.
■ Clean all components of the heater with pressurized air,
a dry brush, or a dry cloth.
Maintenance Instructions
BEFORE EACH USE:
1. The area surrounding the heater shall be kept clear
and free from combustible materials, gasoline, and
other flammable vapors and liquids.
2. Check for gas leaks in all gas lines or hoses.
3. Inspect all gas hoses for nicks, cuts, or corroded
fittings. Replace the complete gas hose assembly if
defects are found.
4. Review all heater labels, such as warnings, wiring
diagrams, instructions, etc. for legibility. Ensure none
are cut, torn, or damaged. Any damaged labels must
be replaced immediately.
5. Check all wiring, associated terminals, and electrical
components within the heater for corrosion, frayed or
cut insulation, tight connections, etc. Repair or replace
as needed.
ANNUALLY:
1. Have your gas supplier check all gas piping for leaks or
restrictions in the gas lines.
2. Gas regulators must be inspected periodically to make
sure that the regulator’s vent is not blocked. Debris,
insect nests, insects, snow, or ice on a vent can cause
excess pressure at the heater.
3. Regulators can wear out and function improperly.
Have your gas supplier check the date codes on the
regulators and check delivery pressures to ensure that
all regulators are reliable.
4. Have your gas supplier clean out the sediment trap to
remove any gas line contamination.
Service Instructions
WARNING
Burn Hazard
■ Some heater surfaces are hot for a period of
time after the heater has been shut down.
■ Allow the heater to cool before performing
service, maintenance, or cleaning.
■ Failure to follow this warning will result in
burns causing injury.
WARNING
Fire and Explosion Hazard
■ Do not disassemble or attempt to repair any
heater components or gas train components.
■ All component parts must be replaced if
defects are found.
■ Failure to follow this warning will result in
fire or explosions, causing property damage,
injury, or death.
WARNING
■ This heater can start at anytime.
■ Only qualified gas heater service personnel
shall service and repair this heater.
■ Before servicing or repair:
- Close all fuel supply valves
- Disconnect the heater’s electrical supply.
■ Failure to follow this warning can lead to
electrical shock or burns, resulting in injury
or death.
Содержание Bloom 400
Страница 29: ...Bloom 400 Greenhouse Heater Owner s Manual Bloom 400 29 Notes...
Страница 32: ...Bloom 400 Greenhouse Heater www lbwhite com Owner s Manual Bloom 400 32 Notes...
Страница 62: ...Calentador para Invernadero Bloom 400 Manual del usuario Bloom 400 29 Notas...
Страница 65: ...Calentador para Invernadero Bloom 400 www lbwhite com Manual del usuario Bloom 400 32 Notas...
Страница 95: ...Bloom 400 R chauffeur de serre Manuel du propri taire Bloom 400 29 Notes...
Страница 98: ...Bloom 400 R chauffeur de serre www lbwhite com Manuel du propri taire Bloom 400 32 Notes...