Bloom 400 Greenhouse Heater
www.lbwhite.com
Owner’s Manual • Bloom 400
22
Troubleshooting Guide
READ THIS ENTIRE SECTION
BEFORE BEGINNING TO
TROUBLESHOOT PROBLEMS.
The following troubleshooting guide provides
systematic procedures for isolating equipment
problems.
THIS GUIDE IS INTENDED
FOR USE BY A QUALIFIED GAS
HEATER SERVICE PERSON. DO NOT
ATTEMPT TO SERVICE THESE HEAT-
ERS UNLESS YOU HAVE BEEN
PROPERLY TRAINED.
TEST EQUIPMENT REQUIRED
The following test equipment will be required to
troubleshoot this system with minimal time and
effort.
• Digital Multimeter - for measuring AC voltage and
resistance.
• Pressure Gauge - for checking inlet and pres
-
sures at the gas control valve against dataplate
rating.
Ensure all wires and electrical connections are in
good condition before beginning to troubleshoot.
Refer to the system operation sequence in this sec
-
tion to gain an understanding as to how the equip
-
ment operates during a call for heat. Understanding
the sequence of operation is important as it relates
to problem solving.
The heater has a red status light.
The
light will flash a specific pattern depending upon the
problem which is diagnosed. If the light is flashing,
the flash pattern will be followed by a pause and
then a repeat of the flash pattern until the problem
is corrected. Use the light to help diagnose the
problem.
Troubleshooting Flow Charts are provided to elimi-
nate problems. To use the flow charts effectively,
you must first identify the problem.
HEATING MODE
Page
Red light is not on .................................................... 24
Red light is flashing:
A. One Time............................................................. 24
B. Two Times ........................................................... 25
C. Three Times ........................................................ 26
D. Four Times .......................................................... 26
D. Five Times........................................................... 26
VENTILATION MODE
A. Motor does not run .............................................. 27
B. Motor hums, does not run ................................... 27
Components should be replaced only after each step has
been completed and replacement is suggested in the flow
chart. Refer to the Servicing sections as necessary to
obtain information on disassembly and replacement proce
-
dures of the component once the problem is identified by
the flow chart.
HEATING DIRECT IGNITION OPERATION SEQUENCE:
• Voltage delivered to motor relay (Heat) and to ignition
control terminal L1.
• Red light on control panel is illuminated.
• Ignition control performs self- safety check.
- Internal components are tested.
• Ignition sequence begins:
- Ignition control sends 120 VAC to air pressure switch
from terminal PSO.
- Ignition control sends 120 VAC to motor (Heat) relay
from terminal IND.
- Motor relay receives voltage from ignition
control.
- Motor relay coil closes and sends voltage to
start motor.
- Air pressure switch closes.
- 120 VAC is returned to ignition control
terminal PSI.
- Ignition control sends high voltage to igniter.
- Igniter sparks.
- Ignition control sends 120 VAC to solenoid valve.
- Solenoid valve opens.
- Gas ignites.
- Flame sense proving occurs
- Ignition spark is stopped.
- Gas valve stays open.
- Room warms to desired temperature.
- Temperature controller is satisfied.
- Heater shuts down
• Process starts again on a call for heat.
WARNING
■ This heater can start at any time.
■ Troubleshooting this system may require oper
-
ating the unit with voltage present and gas on.
Be careful when working on the heater.
■ Failure to follow this warning may result in
property damage, personal injury or death.
Содержание Bloom 400
Страница 29: ...Bloom 400 Greenhouse Heater Owner s Manual Bloom 400 29 Notes...
Страница 32: ...Bloom 400 Greenhouse Heater www lbwhite com Owner s Manual Bloom 400 32 Notes...
Страница 62: ...Calentador para Invernadero Bloom 400 Manual del usuario Bloom 400 29 Notas...
Страница 65: ...Calentador para Invernadero Bloom 400 www lbwhite com Manual del usuario Bloom 400 32 Notas...
Страница 95: ...Bloom 400 R chauffeur de serre Manuel du propri taire Bloom 400 29 Notes...
Страница 98: ...Bloom 400 R chauffeur de serre www lbwhite com Manuel du propri taire Bloom 400 32 Notes...