Operation
Settings protection
Some settings can be protected from modications.
Settings protection can only be enabled and disabled from LA Network Manager. Refer to the
LA Network Manager
Help and the
Settings Protection
technical bulletin.
When settings protection is enabled, some settings are completely locked, and the protection on the others can be
temporarily bypassed by a 4-digit PIN code.
setting
protection
quick access to gain on OUT1 to OUT4
locked
LOAD PRESET FACTORY
PIN code protected
STORE PRESET
PIN code protected
DELETE PRESET
locked
PRESET PARAMETERS (all parameters)
PIN code protected
CLEAR GROUP PARAMS
PIN code protected
NETWORK ADDRESS
PIN code protected
RESET TO FACTORY DEFAULT SETTINGS?
locked
When settings protection is enabled and a user tries to modify a setting:
• Locked settings:
• Screen displays
ACCESS LOCKED
.
• Settings cannot be modied.
• Press the ESC key to cancel.
• PIN code protected settings:
• Screen display
ENTER PIN
.
• Enter the PIN code to temporarily bypass the protection or press the ESC key to cancel.
ACCESS
LOCKED
ENTER PIN:
? ? ? ?
LA4X owner's manual (EN) version 14.1
59
Содержание LA4X
Страница 1: ...LA4X owner s manual EN ...
Страница 81: ...Approvals Approvals LA4X owner s manual EN version 14 1 81 ...