Corrective maintenance
Troubleshooting and diagnosis
For any issue, consider the diagnosis tables for the possible causes and inspection procedures (if any).
Before applying any procedure, consider the
Exploded view
(p.68) to get acquainted with the disassembly/
reassembly procedures to perform before and after.
Interface issues
“black screen" and no LEDs when the controller is on
possible cause
diagnosis / procedure
power cord is not connected
• Check that the power cord is connected to mains.
• Check that the powerCON is properly connected and
locked.
mains failure or incompatible voltage
Check that mains are available and that voltage is
compatible ( 100 V AC - 240 V AC ± 10%, 50 Hz - 60
Hz ).
power cord damaged
Inspect the power cord. If necessary, replace it.
amplied controller on standby
Connect the amplied controller to a computer running LA
Network Manager (the L-NET connector LEDs turn on) and
switch the amplied controller to the operating mode.
other causes
Contact L-Acoustics.
"grey screen": LCD screen lit but nothing displayed
possible cause
diagnosis / procedure
condensing humidity
Put the controller in a non-condensing environment and
wait until dry.
start-up / rmware issue
• Power off and on again.
• Check if LA Network Manager detects the amplied
controller.
• Update the rmware.
other causes
Contact L-Acoustics.
62