Corrective maintenance
Other messages
System Message
Update error
Displayed if the rmware update has failed. Try to restart the unit. If the issue persists,
check that each L-NET cable is in working order and is correctly plugged on both
ends, and relaunch the update process. If the issue persists, contact L-Acoustics.
High temp on ch #
Channel attenuated
Displayed if temperature at an output channel is above 60° C. The signal delivered
at the output channel is attenuated until temperature returns to nominal conditions.
Over temp on ch #
Channel muted
Displayed if temperature at an output channel is above 65° C. The signal delivered
at this output channel is muted until the temperature returns to nominal conditions.
System Message
Fan blocked
Displayed if a fan is faulty. The unit remains operational but there is a risk of
temperature rising.
Speaker fault on ch #
Channel muted
Displayed if the unit detects a short-circuit fault in the speaker coil of the connected
enclosure. The output channel is muted to avoid a potential risk of physical harm
and further damages to the product. Verify the connected loudspeaker enclosures.
Disconnect or replace the faulty enclosure, then unmute the output channel.
For temperature-related messages
possible cause
diagnosis / procedure
room temperature is too high / too low
Make sure room temperature is within amplied controller
operating condition range (0º C / 32º F to +50º C / 122º F).
foam lter clogged, inside of amplied controller dusty Clean or replace the foam lter, clean the amplied controller
with an air blower.
amplied controller is not getting enough cool air
Install the amplied controller in an open area so that the front
and rear panels are not blocked by an external objects or
structure.
If rack-mounted:
• Do not block the ventilation grill with front and back
panels or doors, or use a forced ventilation system.
• When stacking more than one amplied controller, mount
them directly on top of one another or close the free
spaces with blank panels.
channel resources are solicited to their limits
Monitor the channel LED meter:
In case of persistent high level or clip, reduce the audio source
output level (refer to the third-party documentations) or the
gain value on the channel.
loudspeaker impedance too low
Check that nothing causes a short-circuit at the output
(incorrect cabling scheme, damaged cable or short-circuit in
the speaker voice coil).