Technical description
Power supply and amplier section
The Class D amplication circuits ensure the LA4X energy-efciency for minimal heat dissipation. LA4X delivers 4 x
1000 W RMS into 8 or 4 Ω with record hold times. Besides the high raw power rating at 8 Ω, the ability to deliver
energy (power x hold time) yields the best performance from loudspeaker systems, especially in LF reproduction.
The LA4X is a green amplied controller that relies on a universal SMPS (Switch Mode Power Supply) suitable for mains
from 100 to 240 V (±10%). The SMPS features a PFC (Power Factor Correction) which maximizes the amplier efciency
and takes advantage of nearly 100% of the electrical power available with a very high tolerance to unstable mains.
The PFC allows the LA4X to deliver as much power from a 10 A line as from a 16 A line on a conventional amp. This
represents a reduction of the electrical power requirements (cable gauge, power conditioning, etc.) for substantial
savings.
Speaker outputs
LA4X features four speakON connectors for loudspeaker outputs.
Speaker protection
The L-DRIVE transducer protection system provides a dual analysis of both signal intensity and voltage in real-time and
RMS. Under extreme conditions, when component membranes reach the over-excursion zone or if the coil temperature
reaches a critical point, L-DRIVE is activated and acts as a power regulator.
As a result, the amount of power delivered at any channel is adjusted to the dynamic and thermal capacity of each
individual transducer.
Monitoring and control
User interface
The front panel user interface provides:
• Real-time monitoring functionalities via the LED display (signals presence and level) and the LCD screen (system
parameters).
• Instant access to navigation and parameters control using the encoder wheel and the six keys.
See also illustration in section
Front and rear panels
(p.12).
Refer to section
Operation
(p.27) for detailed operating instructions.
L-NET remote control network
The integration of the L-NET Ethernet-based network, with its high speed data transfer protocol up to 1 Gbit/s, allows up
to 253 amplied controllers to be controlled and monitored in real-time from LA Network Manager.
Multiple network topologies such as daisy-chain, star and hybrid are congurable. The computer running LA Network
Manager and the amplied controllers are connected to each other using industry standard CAT5e U/FTP cables (or
higher category) tted with RJ45 connectors.
The LA4X connects to the network via the two etherCON sockets located on its rear panel.
Refer to the
LA Network Manager
Help for detailed operating instructions.
Third party management solutions
L-Acoustics provides SNMP support to facilitate the integration via third party control and monitoring systems.
L-Acoustics is a certied member of the Crestron
®
and Extron
®
partner programs, and provides software modules allowing
control integration into their automation systems.
L-Acoustics provides a plug-in for control and monitoring of LA4X and LA12X on the QSC Q-SYS platform.