Multisystem Ignition Analyzer
- 6 -
display.
◆
SPW (Spark Plug Wire): This setting apply to all the ignition systems
equipped with high voltage spark plug wire ( i.e.:Conventional distributor,
magneto, distributorless or waste spark ignition systems ).
◆
COP (Coil On Plug): This setting apply to the ignition systems which
the ignition coil is mounted near the spark plug or on top of the spark plug.
3.3.3 Engine Cycles button
◆
Press the
“
Engine Cycles
”
button to select the number of cycles for
the engine under testing. The number of cycles will change between 2
cycles, 4 cycles and DIS setting each time the button is pressed. The
selected setting will be shown on the display.
◆
In SPW (Spark Plug Wire) measurement mode, it can be set to: 2 or 4
cycles or DIS ( Distributorless or waste spark ignition system ).
◆
In COP ( Coil on Plug ) measurement mode, it can be set to: 2 or 4
cycles.
3.3.4 F1 / Calibrate button
◆
Press this button will change the measurement which shown on the
main display. There are three measurements to select: RPM, spark burn
time, and spark peak voltage. The measurement functions will be changed
each time the button is pressed momentarily.
◆
Press this button for 3 seconds to start the automatically calibration of
the unit, enter the COP module type under testing. While calibrating, the
screen will display
“
Calibrating please wait
”
, it will turn back to the normal
after accomplishing the procedure ( about 3 seconds ). The calibration
function is disable when in SPW mode.
3.3.5 F2 button
◆
Press the button momentarily will change the display of the two
secondary displays. There are two possible selections: the two
measurements not shown in the main display or the Maximum and
Minimum readings of the main display. Press the button for three seconds
to turn on/ off the display backlight.