Multisystem Ignition Analyzer
- 5 -
reading, RPM or the spark burn time with the selected measurement units and/ or
functions.
3.2.8 Main display
Press the
“
F1/Calibrate
”
button, the main display can be set to show the engine
RPM, spark KVolt or spark burn time.
3.2.9 Functions and measurement units
Displays the measurement units and / or the functions of the main display. The
selected functions with measurement units will show as below.
Display
Function
Measurement units
RPM
Tachometer
RPM (Revolutions per minute)
Burn Time mS
Spark plug burn time
mS (Milliseconds)
Spark KVolt
Spark plug peak voltage
KVolt (1000 x Volt)
3.3 Buttons description and operation
3.3.1 Power ON/OFF and Reset button
◆
When the instrument is off, press the
“ Power / Reset” button until the
instrument turns on ( about 1 second).
◆
When the instrument is on, press the
“
Power / Reset
”
button until the
instrument turns off (about 3 seconds).
◆
When the instrument is on, press the
“
Power / Reset
”
button
momentarily to reset the maximum and minimum and capture values.
Note: In order to prolong the battery life, the instrument will automatically turn off after
3 minutes of being idle ( i.e. No button pressed and no input signal). When not
in use, turn off the instrument manually will prolong the battery life.
3.3.2 Ignition System button
◆
Press the
“
Ignition system
”
button to select the ignition system
measurement mode that matches the ignition system of the engine under
diagnosing, explain as below. The selected setting will be shown on the
Содержание KM20