Kzyee KM20 Скачать руководство пользователя страница 16

  Limited 90 Day Warranty 

 

 

KZYEE makes every effort to assure that its products meet high quality and durability 
standards,  and  warrants  to  the  original  purchaser  that  this  product  is  free  from 
defects  in  materials  and  workmanship  for  the  period  of  90  days  from  the  date  of 
purchase.  This  warranty  does  not  apply  to  damage  due  directly  or  indirectly,  to 
misuse,  abuse,  negligence  or  accidents,  repairs  or  alterations  outside  our  facilities, 
criminal  activity,  improper  installation,  normal  wear  and  tear,  or  to  lack  of 
maintenance. We shall in no event be liable for death, injuries to persons or property, 
or for incidental, contingent, special or consequential damages arising from the use 
of  our  product.  Some states do  not  allow  the  exclusion or  limitation of  incidental  or 
consequential damages, so the  above limitation  of  exclusion  may  not  apply  to  you. 
THIS  WARRANTY  IS  EXPRESSLY  IN  LIEU  OF  ALL  OTHER  WARRANTIES, 
EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY 
AND FITNESS. 
 
To take advantage of this warranty, the product or part must be returned to us with 
transportation  charges  prepaid.  Proof  of  purchase  date  and  an  explanation  of  the 
complaint must accompany the merchandise. If our inspection verifies the defect, we 
will either repair or replace the product at our election or we may elect to refund the 
purchase price if we cannot readily and quickly provide you with a replacement. We 
will return repaired products at our expense, but if we determine there is no defect, or 
that the  defect  resulted  from causes  not  within  the scope  of  our  warranty,  then  you 
must bear the cost of returning the product. 
 
This  warranty  gives  you  specific  legal  rights  and  you  may  also  have  other  rights 
which vary from state to state. 

 

 

 

 

 

 

 

 

 

Содержание KM20

Страница 1: ......

Страница 2: ...on and operation 5 3 4 Measurement procedures 7 3 5 Additional functions 11 4 Application information 12 4 1 Taking measurements 12 4 2 Diagnostic using spark burn time and spark KVolt readings 12 4 3...

Страница 3: ...lease do not operate the instrument when the battery cover is off In order to avoid electrical shock or damage to the instrument please do not exceed the specified input limits When using this instrum...

Страница 4: ...100K 1 5 nF Minimum Input Protection 42 VDC Max Spark KV 0 to 50 Kv Repeatability 3 1 LSD Spark burn time 0 to 10 ms Accuracy 0 1ms 3 OPERATING INSTRUCTION 3 1 Instrument Description 1 Capacitive pic...

Страница 5: ...the absolute minimum value it should be replaced a new battery in case of malfunction 3 2 3 Number of Cycles Displays the number of cycles strokes selected 2 4 or DIS 3 2 4 Ignition System Displays t...

Страница 6: ...operation 3 3 1 Power ON OFF and Reset button When the instrument is off press the Power Reset button until the instrument turns on about 1 second When the instrument is on press the Power Reset butto...

Страница 7: ...In COP Coil on Plug measurement mode it can be set to 2 or 4 cycles 3 3 4 F1 Calibrate button Press this button will change the measurement which shown on the main display There are three measurement...

Страница 8: ...tor cap ignition coil ignition module and other ignition system components carefully for damage or leaks If there is any damage or leaks please do not use the instrument Please do not touch the capaci...

Страница 9: ...is a relative measurement it s used to compare the ignition system performance in each cylinder It can diagnostic the common problems by comparing the spark KVolt between different cylinders such as...

Страница 10: ...les it may cause false readings In order to reduce interference from other ignition modules the nearby ignition modules should be completely covered with pieces of aluminum foil make sure that the alu...

Страница 11: ...spark burn time and RPM measurements are not sensitive to the exact position of the capacitive pick up relative to the spark plug wire but it has to be placed so the instrument can detect the signal...

Страница 12: ...type of the ignition module and compensates for the difference in waveform and signal strength Once the instrument calibrated one of ignition modules of the engine under test the spark KVolt measureme...

Страница 13: ...the RPM by using the tachometer function of the instrument 4 2 Diagnostic using spark burn time and spark KVolt readings Some changes of the spark burn time and spark KVolt readings between different...

Страница 14: ...e gap of the spark plug is too small Dirty or the damaged spark plug insulator or boot allows the spark tracking across the insulator The core of the spark plug wire is broken The break is located bet...

Страница 15: ...display turns off 5 2 Cleaning When not in use please keep the instrument in the carrying case do not subject it to dampness or severe heat or cold Do not use the instrument in rain use a clean paper...

Страница 16: ...r consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABIL...