Multisystem Ignition Analyzer

 

 

- 11 - 

 

or 

“F1 /Calibrate” (Cylinders Decrease ) button to adjust the scale value.   

 

3.5 Additional functions   
3.5.1 Minimum and Maximum functions 

(For COP and SPW modes) 

This  instrument  remains  the  record  of  the  minimum  and  maximum  readings  of  the 
function currently selected. 
1-  In  order  to  display  the  minimum  and  maximum  readings  of  the  main  display, 

press the 

F2

  button if not already selected. 

2-  In order to reset the minimum and maximum readings, press the 

Power /Reset

 

button momentarily. These values will be reset after turning on the instrument. 

 

3.5.2 Spark KVolt calibration function 

(For COP mode only) 

In  order  to  measure  the  spark  KVolt  in  Coil  on  Plug  and  Coil  near  Plug  ignition 
systems, this instrument requires the user to calibrate the instrument. This calibration 
uses  the  measurement  values  obtained  during  the  procedure  to  find  the  optimal 
measurement  parameters  or  a  particular  type  of  the  ignition  module,  and 
compensates for the difference in waveform and signal strength. 

  Once the instrument calibrated one of ignition modules of the engine under test, 

the spark KVolt measurement will relative to the calibration value. 

  Follow  the  procedure  as  described  in 

“3.4.2 Measuring in Coil on Plug and Coil 

near Plug ignition systems

” to calibrate the instrument. 

 
 
 
 
 
 
 
 

 
 

                       

  Fig. 7 

– Display during calibration 

Notes: 

  The  instrument  will  display  the  default  baseline  value  of 

“10.0  spark  KVolt” 

immediately  after calibration. All  the  spark  KVolt  measurements  obtained  thereafter 
will relative to the calibration value module. 

  The calibration does not have any influence on the spark burn time or the PRM 

measurement. (These are absolute). 

  The  Spark  KVolt  values  obtained  before  and  after  calibration  may  not  be 

comparable if calibrate the instrument again. 

  The instrument will display a false 

“0.0 Spark KVolt” reading when measuring the 

spark KVolt on Coil on Plug and Coil near Plug systems if not calibrated. 
 

3.5.3 Auto power off

   

In  order  to  prolong  the  battery  life,  the  instrument  will  automatically  power  off  after 

Содержание KM20

Страница 1: ......

Страница 2: ...on and operation 5 3 4 Measurement procedures 7 3 5 Additional functions 11 4 Application information 12 4 1 Taking measurements 12 4 2 Diagnostic using spark burn time and spark KVolt readings 12 4 3...

Страница 3: ...lease do not operate the instrument when the battery cover is off In order to avoid electrical shock or damage to the instrument please do not exceed the specified input limits When using this instrum...

Страница 4: ...100K 1 5 nF Minimum Input Protection 42 VDC Max Spark KV 0 to 50 Kv Repeatability 3 1 LSD Spark burn time 0 to 10 ms Accuracy 0 1ms 3 OPERATING INSTRUCTION 3 1 Instrument Description 1 Capacitive pic...

Страница 5: ...the absolute minimum value it should be replaced a new battery in case of malfunction 3 2 3 Number of Cycles Displays the number of cycles strokes selected 2 4 or DIS 3 2 4 Ignition System Displays t...

Страница 6: ...operation 3 3 1 Power ON OFF and Reset button When the instrument is off press the Power Reset button until the instrument turns on about 1 second When the instrument is on press the Power Reset butto...

Страница 7: ...In COP Coil on Plug measurement mode it can be set to 2 or 4 cycles 3 3 4 F1 Calibrate button Press this button will change the measurement which shown on the main display There are three measurement...

Страница 8: ...tor cap ignition coil ignition module and other ignition system components carefully for damage or leaks If there is any damage or leaks please do not use the instrument Please do not touch the capaci...

Страница 9: ...is a relative measurement it s used to compare the ignition system performance in each cylinder It can diagnostic the common problems by comparing the spark KVolt between different cylinders such as...

Страница 10: ...les it may cause false readings In order to reduce interference from other ignition modules the nearby ignition modules should be completely covered with pieces of aluminum foil make sure that the alu...

Страница 11: ...spark burn time and RPM measurements are not sensitive to the exact position of the capacitive pick up relative to the spark plug wire but it has to be placed so the instrument can detect the signal...

Страница 12: ...type of the ignition module and compensates for the difference in waveform and signal strength Once the instrument calibrated one of ignition modules of the engine under test the spark KVolt measureme...

Страница 13: ...the RPM by using the tachometer function of the instrument 4 2 Diagnostic using spark burn time and spark KVolt readings Some changes of the spark burn time and spark KVolt readings between different...

Страница 14: ...e gap of the spark plug is too small Dirty or the damaged spark plug insulator or boot allows the spark tracking across the insulator The core of the spark plug wire is broken The break is located bet...

Страница 15: ...display turns off 5 2 Cleaning When not in use please keep the instrument in the carrying case do not subject it to dampness or severe heat or cold Do not use the instrument in rain use a clean paper...

Страница 16: ...r consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABIL...

Отзывы: