19
NOTE
: If a mutual end is used in a lineup, the proper additional pieces of trim should be used.
Waste Outlet (Drip Pipe) Description and Location
These cases are equipped with 1 ½" M-NPT waste outlet connection that terminates in the center of the
refrigerator below the insulated bottom. The water seal trap is shipped unattached for field installation.
NOTE
: Improperly installed drip pipes can seriously effect the operation of this case and result in
increased maintenance costs. Listed below are some general rules for drip pipe installation:
•
Never use a double water seal.
•
Never use a pipe smaller than the size pipe or water seal supplied with the case.
•
Always provide as much fall as possible in drip pipe. (1" fall for each 4' of drip pipe.)
•
Avoid long runs in drip pipe, which make it impossible to provide maximum fall in pipe.
•
Provide a drip space between drip pipe and floor drain or sewer connection.