The generator of your KYMCO UXV500iG has been engineered to be reliable and easy-to-maintain. The generator
does not need period maintenance other than a monthly check of the GFCI switches. Please review this section for
the basic care related to the generator components of your UTV.
GFCI Switch Checks
Each month perform a test of the Leakage Switch and the Overload Switch on the GFCI breaker on the Generator Control
Panel. Follow the procedure listed below.
Leakage Switch
1
1
1
1
1
:
Start the generator normally. Do not connect any electrical devices to the power
output sockets. Press the yellow button and the 30A switch will automatically turn
off. Turn off the generator and reset the 30A switch to the ON position.
Overload Switch
1
1
1
1
1
:
For this test the generator does not need to be operated. With the Generator Main
(keyed) Switch ON, press the red button and the 30A switch will automatically
turn off. Turn off the generator and reset the 30A switch to the ON position.
2
2
2
2
2
1
1
1
1
1
Electrical Output Sockets
Inspect the output sockets (and any cords you use to power electrical devices for corrosion) and verify their connections and
snug and secure.
Содержание UXV500iG
Страница 84: ...82 PERIODIC MAINTENANCE SCHEDULE Continued on following page...
Страница 105: ...103 KYMCO USA LIMITED WARRANTY...
Страница 106: ...104 EPA EMISSION WARRANTY...
Страница 108: ...106 OTHER MAINTENANCE RECORD DATE MILEAGE SERVICE PERFORMED NOTES...
Страница 109: ...107 DATE MILEAGE SERVICE PERFORMED NOTES REPAIR OTHER SERVICE RECORD...
Страница 112: ...5 Stan Perkins Road Spartanburg SC 29307 Telephone 864 327 4744 FAX 864 327 4745 Prepared July 2014 T200 UCA0AA A7...