Trouble shooting guide
Problem
Cause
Remedy
Incorrect distribution rotation.
Metering unit encrusted.
Clean metering unit.
Irregular drive.
Friction point in metering unit.
Check the condition of the
drive (condition of gears,
sprockets, chains and
tensioners).
Uneven spreading.
Too tight a bend in the seed
delivery pipe.
Shorten the pipe to eliminate
the bend.
Moisture problems.
Damp fertilizer will not flow, do
not use fertilizer unless it is dry.
No distribution.
Applicators blocked.
Clean the applicators.
Pipes blocked.
Clear or replace the tube.
Do not work when the tube
inside are too wet.
The safety system shear bolt
has sheared.
Replace the components.
Distributions disengaged.
Check that the lynch pin is in
position and locked.
Fertilizer forming blocks.
The hopper must be emptied at
the end of each work day or for
long parking periods.