Optional equipment
Precision Seed Drills
MAXIMA 2 M
149
Trouble shooting guide
Problem
Cause
Remedy
Incorrect distribution rotation.
Metering unit encrusted.
Clean metering unit.
Irregular drive.
Friction point in metering unit.
Check the condition of the
drive (condition of gears,
sprockets, chains and
tensioners).
Uneven spreading.
Metering unit encrusted.
Clean metering unit.
Friction point in metering unit.
Check the condition of the
drive (condition of gears,
sprockets, chains and
tensioners).
No distribution.
Pipes blocked.
Clear or replace the tube.
Too tight a bend in the seed
delivery pipe.
Shorten the pipe to eliminate
the bend.
Blocked venturi.
Clean the venturi.
Sealing loss.
Worn foils.
Replace foils.
Clogging inside the hopper.
Product remained too long
inside the hopper during wet
weather
Never leave microgranulates
inside the hopper or they will
form compact blocks.