33
9.
Checking the balance of the metering slides
Before each season and regularly during the season, the metering slides should be
checked to ensure that they open simultaneously and evenly. This can be done by
placing the
∅
28 mm lower link pins in both shutter apertures (Photo 7 shows a
lower link pin placed in a shutter aperture that, for better clarity, has not been in-
stalled in the hopper floor).
To correctly check the slide position, both pins must be held vertically from under
the floor.
When the slide position is correct, the application rate indication lever must read
56
.
Photo 7
Attention:
Metering and open/close shutter slides can cause crushing
and cutting injuries if attention is not paid during all balancing opera-
tions. Never activate the hydraulic open/close shutter slide while under-
taking any adjustment and balancing operations (
Injury and damage
danger!
)
If the application rate indication lever does not read
56,
release the quadrant scale by
unscrewing the three locking bolts (Photo 8, No.10) and slide the scale until the va-
lue
56
is achieved. Retighten the three bolts.