KFU 2-/4-
252
Modulation Controller
No. Description Unit
Setting
range
Chapter
753 Operation mode
-
Selection
16.5.6
755 Reference Imr lower limit
A
0.01
I
FUN
... ü
I
FUN
16.5.6.1
756 Control deviation limitation
%
0.00 ... 100.00
16.5.6.1
Speed Sensor Monitoring
760 Operation mode
-
Selection
17.7.3
761 Timeout: Signal fault
ms
0 ... 65000
17.7.3
762 Timeout: Track fault
ms
0 ... 65000
17.7.3
763 Timeout: Direction of rotation fault
ms
0 ... 65000
17.7.3
Speed controller
766 Source of actual speed value
-
Selection
16.5.3
Torque Controller
767 Frequency upper limit
Hz
-999.99 ... 999.99
16.5.2
768 Frequency lower limit
Hz
-999.99 ... 999.99
16.5.2
769 Frequency upper limit source -
Selection 16.5.2.1
770 Frequency lower limit source -
Selection 16.5.2.1
778 Reduction Factor Flux
%
20.00 … 100.00
16.5.5
Starting Behavior
779 Min. Flux-Formation Time
ms
1 … 10000
11.1.2
780 Max. flux formation time
ms
1 ... 10000
11.1.2
781 Current during flux formation
A
0.1
I
FUN
... ü
I
FUN
11.1.2
Timer
790 Operation mode Timer 1
-
Selection
14.5.1
791 Time 1 Timer 1
s/m/h 0 ... 650.00
14.5.1.1
792 Time 2 Timer 1
s/m/h 0 ... 650.00
14.5.1.1
793 Operation mode Timer 2
-
Selection
14.5.1
794 Time 1 Timer 2
s/m/h 0 ... 650.00
14.5.1
795 Time 2 Timer 2
s/m/h 0 ... 650.00
14.5.1
Self-configuration
796
SET-UP
Select
- Selection
7.5
Further motor parameters
1190 Stator Resistance
Ohm
0.001 … 100.000
9.2.1
1192 Peak current
A
0.01% I
FUN
…
100 000% ü I
FUN
9.2.7
1199 Change Sense of Rotation
-
Selection
9.2.8
Mux/DeMux
EEPRO
M:
0 … 16
1250 Mux Input Index (write)
-
RAM:
17 … 33
14.5.4
EEPRO
M:
0 … 16
1251 Mux Input Index (read)
-
RAM:
17 … 33
14.5.4
1252
Mux
input
- Selection
14.5.4
1253
DeMux
input
- Selection
14.5.4
Note:
At the control unit KP500 parameter numbers > 999 are displayed hex-