KFU 2-/4-
166
Warning code
Create Warning Mask
536
A 0080 0000
Tctr
37 - Controller Torque Control
A 0100 0000
Rstp
38 - Ramp Stop
A 0200 0000
IxtLtlim
39 - Contr. Intel. Curr. Lim. LT-Ixt
A 0400 0000
IxtStlim
40 - Contr. Intel. Curr. Lim. ST-Ixt
A 0800 0000
Tclim
41 - Contr. Intel. Curr. Lim. Tc
A 1000 0000
MtempLim
42 - Contr. Intel. Curr. Lim. Motor Temp.
A 2000 0000
Flim
43 - Controller Freq. Limitation
The output of a warning message which is activated in
Create Warning Mask
536
is
signaled via “157 - Warning Mask”. The signal can be linked with inverter functions.
Output signals
The output of a warning message is signaled.
157 -
1)
25 -
Warning Mask
2)
Output of a warning message which is activated in
Create
Warning Mask
536
.
1)
For linking with inverter functions
2)
For digital output
14.3.9 Application warning mask
The logic signals of various monitoring functions can be set via the operation mode
for parameter
Create Appl. Warning Mask
626.
As soon as limit switches are reached
or contouring error limits are exceeded, a warning can be issued. The warnings refer
to the parameter values set in error/warning behavior. Depending on the application,
any number of warnings can be configured. This enables internal and/or external
control using a common output signal.
Create Appl. Warning Mask
626
Function
0 -
no change
The configured warning mask is not changed.
2 -
Activate all Warnings
The warnings reports stated are linked in the
warning mask.
10 -
Warning V-belt
The
Operation mode
581
for V-belt monitoring
signals no-load operation of the application.
11 -
Warning pos. SW-Limit-
Switch
1)
Warning message indicating that the positive
SW limit switch has been reached (parameter
Positive SW limit switch
1145
).
12 -
Warning neg. SW-Limit-
Switch
1)
Warning message indicating that the negative
SW limit switch has been reached (parameter
Negative SW limit switch
1146
).
13 -
Warning pos. HW-Limit-
Switch
1)
Warning message indicating that the positive
HW limit switch has been reached.
14 -
Warning neg. HW-Limit-
Switch
1)
Warning message indicating that the negative
HW limit switch has been reached.
15 -
Warning Contouring Error
1)
Warning message, indicating that the contour-
ing error monitoring range adjusted with pa-
rameter
Warning Threshold
1105
has been
left.
102 -
Deactivate all Warnings
All warnings are deactivated.
110 -
Deactivate Warning V-Belt
Warning 10 is deactivated.
111 -
Deactivate Warning pos.
SW-Limit-Switch
Warning 11 is deactivated.
112 -
Deactivate Warning neg.
SW-Limit-Switch
Warning 12 is deactivated.
113 -
Deactivate Warning pos.
HW-Limit-Switch
Warning 13 is deactivated.