146
W9272-8135-1
05/2020
Operation
Operating in emergency situations
In case of emergency, you can switch off the engine and lower the boom manually.
Engine emergency stop
If the engine cannot be stopped with the key, it can be stopped man-
ually.
To stop the engine, pull the knob (1) until the engine stops.
After the engine has stopped, push in the knob.
Manual lowering of the front attachments
The boom and arm can be lowered in case of an engine failure or if malfunctions occur in the hydraulic system.
The starter switch is in the RUN position.
If necessary, lower the boom and the arm with the control levers as described in the "Operating the controls
during excavation work" section (page 117).
If the engine stop button is activated, a message will
appear on the display as shown in the figure on the
right.
The machine may only be taken back into operation af-
ter the malfunction has been eliminated.
Make sure nobody is standing in the lowering area before starting the emergency lowering procedure.
The lowering function is available only for a short time, as it is controlled by the accumulator in the
hydraulic system. The cylinders extend or retract by force of gravity.
1
1
KX060-05_004
STOP
STOP
Содержание U50-5
Страница 1: ...GB COMPACT EXCAVATOR MODEL U50 5 OPERATING INSTRUCTIONS W9272 8135 1 Original 05 2020...
Страница 38: ...36 W9272 8135 1 05 2020 Safety rules...
Страница 54: ...52 W9272 8135 1 05 2020 Description of the machine...
Страница 74: ...72 W9272 8135 1 05 2020 Assembly and functions...
Страница 164: ...162 W9272 8135 1 05 2020 Operation...
Страница 222: ...220 W9272 8135 1 05 2020 Maintenance...
Страница 224: ...222 W9272 8135 1 05 2020 Safety inspection...
Страница 229: ...Lifting capacity of the excavator W9272 8135 1 227 05 2020 Lift point radius Vertical axis Lift point height Lift point...
Страница 234: ...232 W9272 8135 1 05 2020 Software information...
Страница 235: ...Software information W9272 8135 1 233 05 2020...
Страница 236: ......