CANopen
Identifier determination (COB-ID) Communication Object
Page 34
© Fritz Kübler GmbH, Zähl-und Sensortechnik
Object 6508H: Operating Time
This object contains the operating hours of the device. The value is saved in
a non-volatile memory in the encoder. It shows the actual operating time in
0.1-hour steps. When this function is not in use, the value is set to FFFFFFFFh.
Object 6508H
Object Description
Value
Main
INDEX
6508H
Name
Operating time
Object Code
7 (VAR)
Data Type Index
7 (Unsigned32)
Length
1
Value Description
Object Class
C2 Mandatory
Access
ro
PDO Mapping
No
Value Range
Unsigned32
Mandatory Range
NO
Default Value
NO
Object 6509H: Offset Value
This object contains the offset from the current position value of the encoder
to the preset value.
Object 6509H
Object Description
Value
Main
INDEX
6509H
Name
Calculated offset value
Object Code
7 (VAR)
Data Type Index
4 (Integer32)
Length
1
Value Description
Object Class
C2 Mandatory
Access
ro
PDO Mapping
No
Value Range
Integer32
Mandatory Range
NO
Default Value
NO