Diagnostics
function
Page 14
© Fritz Kübler GmbH, Zähl-und Sensortechnik
3.1.1.2
Diagnostics on/off
Switch S2
Value
Status
Diagnostics
4
2
0
On
on
4
2
0
Off
off
Generally, a diagnostics object having the following meaning is sent
every
second
on the bus:
Diagnostics Message OBJECT 2016
Byte
Status byte
Value
Description
unsigned8
Subinde
x
Description
0
00 ...FF
0
Byte LSB
Position
1
00 ...FF
0
....
2
00 ...FF
0
....
3
00 ...FF
0
Byte MSB
Position
4
00 ...FF
0
Byte Status
5
00 ...FF
0
Byte Warnings
6
00 .. FF
0
Byte Operating
Par.
7
00 ...FF
0
Byte Operating
Par.
Switch S2-4
Содержание 9080 Series