FAILURE DIAGNOSIS
19
N
N
N
N
MAINTENANCE PROCEDURE WHEN BATTERY CAN’T BE CHARGED OR CHARGED COMPLETELY
MAINTENANCE PROCEDURE FOR NO ELECTRICITY OF BATTERY
Low charging mileage
Expiration of battery
Check charger, not output
Bad connection of charger's
output plug or wire
Bad connection of charger's
output plug or socket
Abnormal signal of charger,
fake charging
Change battery
Change charger
Pull in the plug or
replace wire
Replace output
plug or socket
N
No electricity left after a long
time of placement
Power key not off
Bad insulation of power line
Over much self discharge of
battery
Long time of placement
Turn off the key and charge
Check leakage of power line
and deal with insulation
Replace battery
N
N
Y
Y
Y